MEHOOPANY, PA —
OSHA Inspection: PROCTER & GAMBLE PAPER PRODUCTS CO
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of PROCTER & GAMBLE PAPER PRODUCTS CO in ROUTE 87, MEHOOPANY, PA 18629 (NAICS 322299). OSHA activity number 315800466.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROCTER & GAMBLE PAPER PRODUCTS CO
- Site address
- ROUTE 87
- City
- MEHOOPANY
- State
- PA
- ZIP
- 18629
- Mailing
- PO BOX 32, MEHOOPANY, PA 18629
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- SIC code (legacy)
- 2679
- Employees
- 2050
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 IIB
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $4,250 · Current $4,250
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) Paper machine 6M: The energy control procedures did not outline the steps for shutting down, isolating, blocking and securing the oscillating wire needle shower, on or about March 24, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
1910.147 C04 I
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Paper machine 6M: Procedures were not developed, documented or utilized for the control of potentially hazardous energy to the wire section oscillating needle shower head, on or about March 24, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
1910.147 D03
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) Paper machine 6M: All energy isolating devices (circuit breaker and control switch) that were needed to control the energy to the oscillating wire needle shower were not physically located and operated in such a manner as to isolate the equipment from the energy source, on or about March 24, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
1910.147 F03 IID
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $4,250 · Current $4,250
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: a) Paper machine 6M: Each authorized employee failed to affix a personal lockout or tagout device to the wire section lock box prior to beginning work on the equipment, as observed on or about March 24, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
1910.212 A01
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $3,400 · Current $3,400
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Buildings 5 and 7: The scrap pad upenders (3) were not sufficiently guarded to prevent access to nip points created between the moving dump unit and the machine frame, as observed on or about April 25, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $3400.00
- — Z (S) $3400.00
1910.178 A05
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
General-duty citation text
29 CFR 1910.178(a)(5): The user did not have the powered industrial truck marked to identify front end attachments other than factory installed which identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) Buildings 35 and 82: Capacity plates on powered industrial trucks equipped with rhino pole attachments were not properly marked, as observed on or about April 25, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
1910.179 B05
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: a) Papermaking 1M/4M: The overhead bridge crane did not have the rated capacity marked on the east side of the crane, as observed on or about April 30, 2012 b) Papermaking 2M/3M: The overhead reel crane did not have the rated capacity marked on the west side of the crane, as observed on or about April 30, 2012. c) Building 44: The overhead bridge crane did not have the rated capacity marked on the east side of the crane, as observed on or about April 30, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
1910.184 E01
- Issued
- Sep 6, 2012
- Abate by
- Sep 11, 2012
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) 3M Paper machine: Alloy steel chain slings (2), used for rigging of the queen roll, were not equipped with permanently affixed identification tags, as observed on or about April 30, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
More inspections at Procter & Gamble Paper Products CO
View Procter & Gamble Paper Products CO's full OSHA safety record →
More inspections in this industry (NAICS 322299)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315800466.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.