GIBSONTON, FL ·
OSHA Inspection: PATRIOT METALS INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PATRIOT METALS INC in 7314 NUNDY AVENUE, GIBSONTON, FL 33534 (NAICS 423930). OSHA activity number 315813402.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PATRIOT METALS INC
- Site address
- 7314 NUNDY AVENUE
- City
- GIBSONTON
- State
- FL
- ZIP
- 33534
- Mailing
- PO BOX 300, GIBSONTON, FL 33534
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- SIC code (legacy)
- 5093
- Employees
- 25
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 27, 2011
- Abate by
- Nov 14, 2011
- Penalty
- Initial $2,380 · Current $1,785 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to the hazard of being struck by fragments of polyvinyl chloride (PVC) plastic pipe in the event that the PVC plastic pipe ruptures. Location: 7314 Nundy Avenue, Gibsonton FL 33760. a. In the canopy ceiling area that houses five balers and a trailer dock station, PVC plastic piping was used in exposed above ground locations to transport compressed air at pressures of around 80 psi for air operated equipment and for cleaning purposes. Violation observed on 09/28/2011. Among other methods, one feasible and acceptable method to correct this hazard is to use cast iron piping or Acrylonitrile-Butadiene-Styrene (ABS) piping in accordance with ANSI/ASME B31.8-1986, Gas Transmission and Distribution Piping Systems standard.
Recent events (2)
- · I (S) $1785.00
- · Z (S) $2380.00
1910.242 B
- Issued
- Oct 27, 2011
- Abate by
- Nov 8, 2011
- Penalty
- Initial $3,570 · Current $2,678 Reduced
Recent events (2)
- · I (S) $2677.50
- · Z (S) $3570.00
1910.1200 E01
- Issued
- Oct 27, 2011
- Abate by
- Nov 29, 2011
- Penalty
- Initial $2,380 · Current $1,785 Reduced
Recent events (2)
- · I (S) $1785.00
- · Z (S) $2380.00
1910.134 C01
- Issued
- Oct 27, 2011
- Abate by
- Nov 14, 2011
Recent events (2)
- · I (O)
- · Z (O)
1910.134 K06
- Issued
- Oct 27, 2011
- Abate by
- Nov 8, 2011
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Patriot Metals INC
View Patriot Metals INC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 315813402.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.