OSHA Inspection: N.G.V. CARPENTRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of N.G.V. CARPENTRY, INC. in 3404 WATERMARK DR., WESLEY CHAPEL, FL 33544 (NAICS 238130). OSHA activity number 315813410.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch N.G.V. Carpentry, INC. — free Get an email when a new federal OSHA severe-injury report for N.G.V. Carpentry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3404 WATERMARK DR.
City
WESLEY CHAPEL
State
FL
ZIP
33544
Mailing
1312 E 149TH AVE, LUTZ, FL 33549
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
7
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 3 exposed
Issued
Aug 24, 2011
Abate by
Sep 5, 2011
Penalty
Initial $2,500 · Current $1,875 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that;
employees were exposed to the hazard of falling from the metal plate
connected wood roof
trusses that were subject to potential movement due to the lack of proper
temporary bracing:
a) 3404 Watermark Drive, Wesley Chapel, south side - Employees were
exposed to a fall as high as 14 feet 10 inches during the installation of
roof
trusses due to the lack of temporary bracing. The lack of the temporary
bracing could cause the roof trusses to collapse. The employer was using
only
short member temporary lateral restraints(spacers) for temporary bracing.
Among one feasible and acceptable method of abatement is to install and
handle the roof trusses in accordance with the Building Component Safety
Information, Guide to Good Practice for Handling, Installing, Restraining
and
Bracing of Metal Plate Connected Wood Trusses.
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $2500.00

1926.501 B01

Serious Gravity 05 1 instance 4 exposed
Issued
Aug 24, 2011
Abate by
Sep 5, 2011
Penalty
Initial $2,500 · Current $1,875 Reduced
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $2500.00

View N.G.V. Carpentry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315813410.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.