LEESPORT, PA —
OSHA Inspection: CURTIS BAY ENERGY, INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CURTIS BAY ENERGY, INCORPORATED in WATER STREET, LEESPORT, PA 19533 (NAICS 562211). OSHA activity number 315886507.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CURTIS BAY ENERGY, INCORPORATED
- Site address
- WATER STREET
- City
- LEESPORT
- State
- PA
- ZIP
- 19533
- Mailing
- 10-A WINGCO LANE, READING, PA 19605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562211
- SIC code (legacy)
- 4953
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 17, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $2,700 · Current $2,025 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falls, slips, or trip hazards at the unloading/loading operation because of the inadequate light levels: (a)Curtis Bay Energy, Incorporated - The employees unloading the local pick-up trucks and transferring the medical waste and sharps to the trailer were provided with 3 footcandles of light from battery powered lantern(s) and this level was not adequate to protect employees from tripping hazards, on or about November 29, 2011. Among other methods, one feasible and acceptable method to correct this hazard is to follow the guidelines noted in the American National Standards Institute (ANSI) Recommended Practice for Lighting Industrial Facilities (RP-7-01), Figure A2-2, page 59. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2025.00
- — Z (S) $2700.00
1910.141 D02 II
- Issued
- Jan 17, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $2,700 · Current $2,025 Reduced
Recent events (2)
- — I (S) $2025.00
- — Z (S) $2700.00
More inspections in this industry (NAICS 562211)