BROWNSVILLE, TX —
OSHA Inspection: IXTAPA DBA RIO TEX NEON SIGNS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of IXTAPA DBA RIO TEX NEON SIGNS INC. in 1425 RUBEN TORRES BLVD, BROWNSVILLE, TX 78521 (NAICS 561790). OSHA activity number 315979377.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IXTAPA DBA RIO TEX NEON SIGNS INC.
- Site address
- 1425 RUBEN TORRES BLVD
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78521
- Mailing
- 1500 MID CITIES DR, PHARR, TX 78577
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 19
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 8, 2011
- Abate by
- Jan 30, 2012
- Penalty
- Initial $2,400 · Current $1,680 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to fall hazards and electrical hazards: On or about October 13, 2011, and at times prior thereto, employees utilized and operated a vehicle-mounted Elliott S70 Skywalk Hi-Reach License plate #O62DP8 with the deficiencies listed below, the employees were exposed to fall hazards and electrical hazards: a.The electrical wiring and connections did not have their protective coverings;terminations were exposed to environmental damage. b.Hydraulic or pneumatic systems for leaks c.Missing or illegible operation markings of manufacture,serial number etc. d.The personnel basket missing its top rail e.No aerial lift maintenance record on last cable change f.Improper winding of wire rope on sheave drum g.Winch hook anchor missing latch Among other methods, one feasible and acceptable abatement method to correct these hazard is to perform maintenance and conduct and record inspections and tests on the vehicle-mounted elevating and rotating aerial ladder in accordance with American National Standard Institute, Vehicle-Mounted Elevating and Rotating Aerial Devices, Standard A92.2-1990, Section 8 for owners and users, as stipulated below: Perform inspections of mobile units at designated intervals for the following items: a.Parts, such as pins, bearings, shafts, gears, rollers, locking devices, chains, chain sprockets, wire ropes, and sheaves for wear, cracks or distortion. b.Electrical systems and components for deterioration or wear including those not readily visible on a frequent inspection.
Recent events (2)
- — I (S) $1680.00
- — Z (S) $2400.00
1910.147 C04 I
- Issued
- Dec 8, 2011
- Abate by
- Jan 30, 2012
- Penalty
- Initial $2,400 · Current $1,680 Reduced