NORTH LAS VEGAS, NV ·
OSHA Inspection: ALTERNATIVE HOSE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALTERNATIVE HOSE in 4436 LAWRENCE STREET, UNIT D, NORTH LAS VEGAS, NV 89081 (NAICS 326220). OSHA activity number 315999441.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALTERNATIVE HOSE
- Site address
- 4436 LAWRENCE STREET, UNIT D
- City
- NORTH LAS VEGAS
- State
- NV
- ZIP
- 89081
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326220
- SIC code (legacy)
- 3052
- Employees
- 3
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
6 citations on file for this inspection.
618037501
- Issued
- Mar 12, 2012
- Abate by
- Mar 15, 2012
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): Duties of employers. The employer shall furnish employment and a place of employment which are free from recognized hazards that are causing or likely to cause death or serious physical harm to his or her employees: a.At the Alternate Hose warehouse area, employees stacked heavy items and merchandise on steel storage racks approximately 20 feet high. The base plate of the column racks were not anchored down to the ground. Reference: ANSI MH16.1:2008 - Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks: Section 1.4.7. Column Base Plates and Anchors. The bottom of all columns shall be furnished with column base plates, as specified in Section 7.2. All rack columns shall be anchored to the floor with anchor bolts capable of resisting the forces by the horizontal and vertical loads of the rack. One feasible means of abatement is to ensure that the base plate of the rack columns be anchored to the ground according to the ANSI MH16.1:2008 Section 1.4.7.n
Recent events (2)
- · L (S) $2100.00
- · Z (S) $3000.00
1910.178 L06
- Issued
- Mar 12, 2012
- Abate by
- Mar 15, 2012
- Penalty
- Initial $2,400
Recent events (2)
- · L (O)
- · Z (S) $2400.00
1910.157 E03
- Issued
- Mar 12, 2012
- Abate by
- Mar 15, 2012
- Penalty
- Initial $600
Recent events (2)
- · L (O)
- · Z (O) $600.00
1910.178 P01
- Issued
- Mar 12, 2012
- Abate by
- Mar 15, 2012
- Penalty
- Initial $600 · Current $420 Reduced
Recent events (2)
- · L (O) $420.00
- · Z (O) $600.00
1910.212 B
- Issued
- Mar 12, 2012
- Abate by
- Mar 15, 2012
- Penalty
- Initial $600
Recent events (2)
- · L (O)
- · Z (O) $600.00
1910.215 B09
- Issued
- Mar 12, 2012
- Abate by
- Mar 18, 2012
- Penalty
- Initial $600 · Current $420 Reduced
Recent events (2)
- · L (O) $420.00
- · Z (O) $600.00