ALBUQUERQUE, NM —
OSHA Inspection: ETHRIDGE TIRE CENTER, LTD.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ETHRIDGE TIRE CENTER, LTD. in 6201 MONTGOMERY BLVD NE, ALBUQUERQUE, NM 87109 (NAICS 811111). OSHA activity number 316115625.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ETHRIDGE TIRE CENTER, LTD.
- Site address
- 6201 MONTGOMERY BLVD NE
- City
- ALBUQUERQUE
- State
- NM
- ZIP
- 87109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 7
- Ownership type
- A
Citations
25 citations on file for this inspection.
90005 A
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $1,050 · Current $525 Reduced
Recent events (2)
- — F (S) $525.00
- — Z (S) $1050.00
90005 A
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
11.5.1.13 NMAC Section 50-9-5(A), NMSA 1978 (New Mexico Occupational Health and Safety Act): Every employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees: 1.Employees performing maintenance repair tasks on automobiles on lifts are exposed to the hazard of lift failure and subsequent release since the emergency locking system is inoperative: A.Bay 1 outside of office, Hanmecson 10K, steel cable for release broken and wrapped around east pillar to keep lock from engaging. B.Fourth bay from office, Hanmescon 14K, pneumatic locks inoperative. C.West wing of garage, north lift, east side; unknown manufacturer, 6- 7k; over centering mechanical lock inoperative. Therefore, employees are working in an environment that is not free from recognized hazards as described by ANSI/ALI ALOIM:2008, Safety Requirements for Operation, Inspection, and Maintenance for Automotive Lifts, para 5.6.2.16. On feasible and acceptable abatement method includes but is not limited to engaging a qualified lift repair vendor that can perform repairs in accordance with the lift manufacturer's recommendations. 2.Employees performing maintenance repair tasks on automobiles on a lift are exposed to the hazard of the automobile falling off of the lift because one of the four lift pads is broken and a substitute spacer must be inserted: A.Second bay from office, unknown manufacturer. Therefore, employees are working in an environment that is not free of recognized hazards as described by ANSI/ALI ALOIM:2008, Safety Requirements for Operation, Inspection, and Maintenance for Automotive Lifts, para 5.6.2.17. One feasible and acceptable abatement method includes but is not limited to replacing the broken pad with a serviceable component. 3.Employees performing maintenance repair tasks on automobiles on lifts are exposed to the hazard of lift failure and release because of a hydraulic leak of the main cylinder: A.West wing of garage, north lift, east side; unknown manufacturer. Therefore, employees are working in an environment that is not free of recognized hazards as described by ANSI/ALI ALOIM:2008, Safety Requirements for Operation, Inspection and Maintenance for Automotive Lifts, para 5.6.3.1. One feasible and acceptable abatement method includes but is not limited to inspecting cylinder surfaces and repairing or replacing damaged areas and replacing seals in accordance with the manufacturer's recommendations or established industry repair practices.
Recent events (2)
- — F (S) $750.00
- — Z (S) $1500.00
1910.101 B
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1910.215 A02
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — F (S) $300.00
- — Z (S) $600.00
1910.215 A04
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (S)
- — Z (S)
1910.215 B09
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (S)
- — Z (S)
1910.215 D03
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (S)
- — Z (S)
1910.253 B04 III
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1910.253 E06 II
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — F (S) $300.00
- — Z (S) $600.00
1910.253 A03
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (S)
- — Z (S)
1910.303 G01 II
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450
Recent events (2)
- — F (O)
- — Z (S) $450.00
1910.304 G05
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1910.305 B02 I
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- — F (S) $375.00
- — Z (S) $750.00
1910.305 G01 IVA
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1910.305 G01 IVC
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (S)
- — Z (S)
1910.334 A02 II
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (S)
- — Z (S)
1910.305 G02 II
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1910.106 E09 IV
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.157 E02
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.1200 E01
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.1200 E01 I
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.1200 F05 I
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.1200 G10
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.1200 H01
- Issued
- Jan 30, 2012
- Abate by
- Jun 29, 2012
Recent events (2)
- — F (O)
- — Z (O)
1910.305 B01 II
- Issued
- Jan 20, 2012
- Abate by
- Jun 29, 2012
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
More inspections in this industry (NAICS 811111)
More inspections in NM
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316115625.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.