Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: BABY BARRIER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BABY BARRIER in 6161 DUNCAN RD, PUNTA GORDA, FL 33951 (NAICS 337215). OSHA activity number 316222694.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baby Barrier for free Get an email when a new federal OSHA severe-injury report for Baby Barrier is published. One employer, no account, unsubscribe in one click.
Establishment
BABY BARRIER
Site address
6161 DUNCAN RD
City
PUNTA GORDA
State
FL
ZIP
33951
Mailing
P.O BOX 512111, PUNTA GORDA, FL 33951
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
SIC code (legacy)
3089
Employees
5
Ownership type
Private (A)
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 3 exposed
Issued
Nov 30, 2011
Abate by
Dec 18, 2011
Penalty
Initial $3,000 · Current $2,250 Reduced
5(a)(1) of the Occupational Safety and Health Act of 1970: The employer
did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees
were exposed to the hazard of being struck by fragments of Thermoplastic
Polyvinyl
Chloride (PVC) Plastic Pipe in the event that the PVC plastic pipe
ruptures.  In the facility
PVC plastic piping was used in exposed above ground locations to transport
compressed air
for the operation of air operated tools and for cleaning purposes.  The
use of PVC plastic
pipe in exposed above ground locations is not recommended by the Plastic
Pipe Institute, and
such use is prohibited by ANSI/ASME B31.8-1986, Gas Transmission and
Distribution
Piping Systems Standard.
Among other methods, two feasible and acceptable abatement methods to
correct
this hazard
are; #1) Replace all existing PVC pipes and fittings with cast iron
materials, or other types
of metal piping, which are rated to transport compressed air safely in
exposed above ground
locations.  #2) Replace all existing PVC pipes and fittings with shatter
resistant Acrylonitrile-
Butadiene-Styrene (ABS) pipe and fittings, which are manufactured for
above ground use of
compressed air.
Recent events (2)
  • · I (S) $2250.00
  • · Z (S) $3000.00

1910.212 A01

Serious Gravity 01 3 instances 1 exposed
Issued
Nov 30, 2011
Abate by
Dec 12, 2011
Penalty
Initial $1,800 · Current $1,350 Reduced
Recent events (2)
  • · I (S) $1350.00
  • · Z (S) $1800.00

1910.215 A04

Serious Gravity 01 1 instance 1 exposed
Issued
Nov 30, 2011
Abate by
Dec 5, 2011
Penalty
Initial $1,800 · Current $1,350 Reduced
Recent events (2)
  • · I (S) $1350.00
  • · Z (S) $1800.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 316222694.