HONOLULU, HI ·
OSHA Inspection: THE BUS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of THE BUS in 811 MIDDLE ST, HONOLULU, HI 96819 (NAICS 488490). OSHA activity number 316272442.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE BUS
- Site address
- 811 MIDDLE ST
- City
- HONOLULU
- State
- HI
- ZIP
- 96819
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488490
- SIC code (legacy)
- 4173
- Employees
- 902
- Ownership type
- Local government (B)
- Industry flags
- Manufacturing health.
Citations
3 citations on file for this inspection.
1910.107 B05 I
- Issued
- Jan 14, 2014
- Abate by
- Jan 22, 2014
- Penalty
- Initial $2,475 · Current $1,733 Reduced
Recent events (2)
- · I (S) $1732.50
- · Z (S) $2475.00
600002 A03
- Issued
- Jan 14, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $2,475 · Current $1,733 Reduced
General-duty citation text
HAR 12-60-2(a)(3) was violated because: The employer failed to anchor column legs on rack systems, thus exposing employees to struck-by and crushed-by hazards. ANSI MH16.1:2008, Specification for the Development, Testing, and Utilization of Industrial Steel Storage Racks, Section 1.4.7 states "All rack columns shall be anchored to the floor with anchor bolts capable of resisting the forces caused by the horizontal and vertical loads on the rack." 12-60-2(a)(3) states "Every employer shall provide safe work places and practices by elimination or reduction of existing or potential hazards. Elimination of existing or potential hazards by design, process substitution, or other appropriate methods is preferred because it eliminates the need for further employee protection. When elimination is not feasible, reduction of existing or potential hazards to acceptable levels, using methods such as engineering or administrative controls, isolation, or guarding, shall be promptly used. When these methods are inadequate to reach acceptable levels, personal protective equipment shall be provided and used." Location: Running Repair (Building B) Storeroom
Recent events (2)
- · I (S) $1732.50
- · Z (S) $2475.00
600002 A03
- Issued
- Jan 14, 2014
- Abate by
- Feb 3, 2014
General-duty citation text
HAR 12-60-2(a)(3) was violated because: The employer failed to regularly inspect rack systems for damage and replace or repair damaged racks. Two shelving units had a bent column leg, thus employees were exposed to struck-by and crushed-by hazards. ANSI MH16.1:2008 Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks, Section 1.4.1(2) states "The owner shall maintain the structural integrity of the installed rack system by assuring proper operation, housekeeping, and maintenance procedures including, but not limited to the following: (1) Prohibit any overloading of any pallet positions and of the overall rack system. (2) Regularly inspect for damage. If damage is found, immediately unload the affected area and replace or repair any damaged columns, beams or other structural components." 12-60-2(a)(3) states "Every employer shall provide safe work places and practices by elimination or reduction of existing or potential hazards. Elimination of existing or potential hazards by design, process substitution, or other appropriate methods is preferred because it eliminates the need for further employee protection. When elimination is not feasible, reduction of existing or potential hazards to acceptable levels, using methods such as engineering or administrative controls, isolation, or guarding, shall be promptly used. When these methods are inadequate to reach acceptable levels, personal protective equipment shall be provided and used." Location: Running Repair (Building B) Storeroom
Recent events (2)
- · I (S)
- · Z (S)
More inspections at The BUS
View The BUS's full OSHA safety record →
More inspections in this industry (NAICS 488490)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 316272442.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.