Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: EDDE DRILLING COMPANY LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EDDE DRILLING COMPANY LLC in FM RD 791, MCMULLEN COUNTY, PEELER RANCH WELL #4, TILDEN, TX 78072 (NAICS 213111). OSHA activity number 316283068.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Edde Drilling Company LLC for free Get an email when a new federal OSHA severe-injury report for Edde Drilling Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
FM RD 791, MCMULLEN COUNTY, PEELER RANCH WELL #4
City
TILDEN
State
TX
ZIP
78072
Mailing
PO BOX 4966, VICTORIA, TX 77903
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
60
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 5, 2012
Abate by
Jul 31, 2012
Penalty
Initial $4,900 · Current $3,920 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized
hazards that
were causing, or likely to cause, death or serious physical harm to
employees in that employees
were exposed to being struck by falling equipment:
On Peeler Ranch well# 4, employee were preparing the rig for circulation
operations.  The employer did not ensure devices or equipment, such as,
but not
limited to, a 2-inch plug valve assembly were assembled and secured in a
manner
to prevent falling prior to elevating the pipe and assembly 30 to 40 feet
above the
drilling floor.
Among other methods, one feasible means to abate this hazard is to
complete the
assembly of devices and equipment at or about the level of the rig floor.
Recent events (2)
  • · F (S) $3920.00
  • · Z (S) $4900.00

1910.151 B

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 5, 2012
Abate by
Jul 31, 2012
Penalty
Initial $4,900 · Current $3,430 Reduced
Recent events (2)
  • · F (S) $3430.00
  • · Z (S) $4900.00

View Edde Drilling Company LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 316283068.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.