REIDSVILLE, NC —
OSHA Inspection: SOUTH / WIN LTD.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SOUTH / WIN LTD. in 606 WALTERS COURT, REIDSVILLE, NC 27320 (NAICS 325612). OSHA activity number 316299403.
Where did this inspection happen?
- Establishment
- SOUTH / WIN LTD.
- Site address
- 606 WALTERS COURT
- City
- REIDSVILLE
- State
- NC
- ZIP
- 27320
- Mailing
- PO BOX 20461, GREENSBORO, NC 27420
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325612
- SIC code (legacy)
- 2842
- Employees
- 21
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
22 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $2100.00
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to fire and/or explosion: a)Fill Area, Finished Product Area - there was no sprinkler system in the facility that would activate in order to suppress fire so that employees could evacuate the facility. There was continual leaking of the filler supply valve that filled the filler bowl with flammable product (flashpoints ranging from 900 Fahrenheit to 930 Fahrenheit), and leaking of the filler bowl valves that filled bottles into a diked area underneath and on the floor adjacent to the diked area. These leaks resulted in a flammable vapor liberation area around the filler bowl. There was unclassified electrical equipment, such as disconnects, conduit, receptacles, and junction boxes in the vapor liberation area. The facility was covered under the PSM standard as a result of the following amounts of flammable materials present in process equipment during the production of flammable products, such as windshield washer antifreeze (-30, -20), de-icer windshield washer fluid (-25), and winter de-icer bug remover windshield washer fluid (-25): 14,645 pounds of flammable chemicals in the Blending Tanks, 10,799 pounds of flammable chemicals in the Re-Work Totes, a maximum of 68,399 pounds of flammable finished product, and 79,200 pounds of flammable raw materials in the Bulk Storage Tanks. REFERENCE: North Carolina Building Code, 1996 edition, Section 2203.1.15.1: 2203.1.15.1 Automatic Sprinkler Systems: Unless exempted by 2203.2 through 2203.14, indoor storage areas and storage buildings shall be protected by an approved automatic sprinkler system. The design of the sprinkler system shall be not less than ordinary hazard, Group 2 in accordance with NFPA 13. For areas of sprinkler operation of less than 3,000 sq ft (280 m2), a density for 3,000 sq ft (280 m2) shall be used. NOTE: Among other means of abatement, one feasible and acceptable method to correct this hazard is to install a sprinkler system in the area containing the flammable liquids.
Recent events (2)
- — F (O)
- — Z (S) $2100.00
1910.106 E03V A
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 C01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.119 D02I
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (O)
- — Z (S) $2100.00
1910.119 D03I
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $3550.00
Recent events (2)
- — F (S) $3550.00
- — Z (S) $2100.00
1910.119 D03II
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.119 E01
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 F01
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 G01I
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 H02II
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.119 H02III
- Issued
- Abate by
Recent events (2)
- — F (S)
- — Z (S)
1910.119 I01
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 J02
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.119 J03
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 J04I
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (O)
- — Z (S) $2100.00
1910.119 K02
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1500.00 Reduced
Recent events (2)
- — F (S) $1500.00
- — Z (S) $2100.00
1910.119 L01
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.119 N
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
1910.178 C02III B
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.305 E01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
Recent events (2)
- — F (S) $2100.00
- — Z (S) $2100.00
1910.307 C02I
- Issued
- Abate by
- Penalty
- Initial $2100.00
Recent events (2)
- — F (S)
- — Z (S) $2100.00
More inspections at SOUTH / WIN LTD.
SPARKS, NV—2014-06-24 00:00:00
SOUTH WIN LTD
LEOMINSTER, MA—2013-10-22 00:00:00
SOUTH/WIN LTD.
REIDSVILLE, NC—2012-01-03 00:00:00
SOUTH / WIN LTD.
REIDSVILLE, NC—2007-11-08 00:00:00
SOUTH / WIN LTD.
View SOUTH / WIN LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 325612)
SALEM, VA—2026-06-11
KIK (VIRGINIA) LLC
SALEM, VA—2026-06-11
KIK (VIRGINIA) LLC
SALEM, VA—2026-05-26
KIK (VIRGINIA) LLC
GARLAND, TX—2026-05-19
ZOBELE USA INC.
ZION, IL—2026-05-11
RITECHEM USA, LLC DBA PCL GLOBAL
More inspections in NC
KERNERSVILLE, NC—2026-07-15
161552 - EDC, INC.
FRANKLINTON, NC—2026-07-15
161551 - LINDSAY PRECAST, LLC
RALEIGH, NC—2026-07-14
161550 - SUNRISE SENIOR LIVING MANAGEMENT, INC.
LAURINBURG, NC—2026-07-14
161549 - AMERICAN WOOD FIBERS, INC.
RURAL HALL, NC—2026-07-14
161546 - CAVERT WIRE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316299403.