CHANTILLY, VA ·
OSHA Inspection: TOTAL MECHANICAL SERVICE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TOTAL MECHANICAL SERVICE INC. in 14514 LEE ROAD, CHANTILLY, VA 20151 (NAICS 238220). OSHA activity number 316489137.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL MECHANICAL SERVICE INC.
- Site address
- 14514 LEE ROAD
- City
- CHANTILLY
- State
- VA
- ZIP
- 20151
- Mailing
- 4692 HELEN WINTER TERRACE, ALEXANDRIA, VA 22312
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- SIC code (legacy)
- 1711
- Employees
- 1
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
510001 A
- Issued
- Jun 7, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $525 · Current $525
General-duty citation text
Title 40.1-51.1(a) Code of Virginia: At 14516-I Lee Road, Chantilly, VA, on April 20th, 2012, the employer, Total Mechanical Service Inc, did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall hazard when accessing the roof when the aluminum extension ladder did not reach above the roof edge. An employee utilized an aluminum extension ladder to access the roof of an approximately 20 foot high building, but the top of the ladder was placed well below the roof edge, requiring the employee to grab onto the roof edge and pull himself up. The extension ladder was missing the manufacturer provided safety and instructional labels. One feasible and acceptable method, among others, to correct this hazard is for the employer to follow the American National Standard for ladders-portable metal-safety requirements (ANSI A14.2-1990), which states in section 8.3.10 "Access to Roof. When single section or extension ladders are used to gain access to a roof, the top of the ladder shall extend at least 1 foot and no more than 3 feet above the point of support at the eaves, gutter or roof line. The ladder should be tied down to prevent slipping before the user ascends onto the roof." ANSI A14.2-1990 also states under section 9, Labeling/Marking Requirements, 9.1.2 "Markings shall be legible and readily visible." and 9.2.1 "The product data information markings in 9.2.2 shall appear on the outside of the lower left rail (climber facing the ladder) and where possible, approximately 4-1/2 to 6 feet from the bottom of the ladder."
1910.23 C01 I
- Issued
- Jun 7, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $525 · Current $525
1910.151 B
- Issued
- Jun 7, 2012
- Abate by
- Aug 12, 2012
- Penalty
- Initial $315 · Current $315
More inspections in this industry (NAICS 238220)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316489137.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.