WINTER PARK, FL ·
OSHA Inspection: GATOR TREE SERVICE, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GATOR TREE SERVICE, INC in 325 BALFOUR DR., WINTER PARK, FL 32792 (NAICS 561730). OSHA activity number 316537992.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GATOR TREE SERVICE, INC
- Site address
- 325 BALFOUR DR.
- City
- WINTER PARK
- State
- FL
- ZIP
- 32792
- Mailing
- 530 CARVER BLVD., ORLANDO, FL 32810
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- SIC code (legacy)
- 0783
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 31, 2012
- Abate by
- Sep 2, 2012
- Penalty
- Initial $1,800 · Current $1,800
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of crushing, falls, or traumatic injuries due to failure of machine components. a) 325 Balfour Dr., Winter Park FL - an employee was exposed to a fall of approximately 35 feet while using a vehicle mounted elevating and rotating work platform. The upper boom cylinders were leaking which caused slack in the cables. The slack in cables caused the cables to come off of the spool/pulley. Among other methods, one feasible and acceptable abatement method to correct this hazard is to: repair the vehicle-mounted elevating and rotating work platform according to the recommendations of a certified mechanic.
1910.67 C02 V
- Issued
- Jul 31, 2012
- Abate by
- Sep 2, 2012
- Penalty
- Initial $1,800 · Current $1,800
More inspections in this industry (NAICS 561730)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 316537992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.