OSHA Inspection: CENTRAL CAROLINA AIR CONDITIONING COMPANY, LLC

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of CENTRAL CAROLINA AIR CONDITIONING COMPANY, LLC in 1402 PINCKNEY STREET, WHITEVILLE, NC 28472 (NAICS 238220). OSHA activity number 316601111.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Central Carolina AIR Conditioning Company, LLC — free Get an email when a new federal OSHA severe-injury report for Central Carolina AIR Conditioning Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1402 PINCKNEY STREET
City
WHITEVILLE
State
NC
ZIP
28472
Mailing
1800-A FAIRFAX RD, GREENSBORO, NC 27407
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
SIC code (legacy)
1711
Employees
100
Ownership type
A
Industry flags
Manufacturing health.

1 citation on file for this inspection.

95012901

Serious 1 instance 1 exposed
Issued
Sep 21, 2012
Abate by
Sep 26, 2012
Penalty
Initial $1,200 · Current $1,200
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees in that
employees were exposed to:
a)Liberty Commons - where an employee was using an eight foot, fiberglass
step-ladder to gain
access to the attic, utilizing the top rung of the ladder.
ABATEMENT NOTE:
a)One acceptable abatement method to correct this hazard is to use an
extension ladder to gain
access to the attic.
Reference a)Hazards are recognized and addressed in ANSI A 14.5-1992
paragraph 9.3.2;  "The user shall
climb or work with the body near the middle of the step or rung.  The user
shall not step or
stand higher than the step or rung indicated on the label marking the
highest standing level of a
ladder.  The user shall not step or stand on:  (1)  A ladder top cap and
the top step of a step or
trestle ladder, or the bucket or pail shelf of a self-supporting ladder.
(2)  The rear braces of a
self-supporting ladder unless they are designed and recommended for the
purpose by the
manufacturer.  (3)  The top step of th extension section of an extension
trestle ladder.  (4)  The
top cap or top step of a combination ladder when it is used as a
self-supporting ladder."porting

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316601111.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.