TOWSON, MD —
OSHA Inspection: SINGER & MITCHELTREE TREE PRESERVATION INC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of SINGER & MITCHELTREE TREE PRESERVATION INC in 19 DIXIE DRIVE, TOWSON, MD 21204 (NAICS 561730). OSHA activity number 316610427.
Where did this inspection happen?
- Establishment
- SINGER & MITCHELTREE TREE PRESERVATION INC
- Site address
- 19 DIXIE DRIVE
- City
- TOWSON
- State
- MD
- ZIP
- 21204
- Mailing
- PO BOX 291, TIMONIUM, MD 21094
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- SIC code (legacy)
- 0783
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
50104 A
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1500.00
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:09/28/12 Location:Middle of the Back Yard at 19 Dixie Drive, Towson, Maryland Condition:The arborist trainee climber/cutter was positioned in a large cherry tree within 10 feet of overhead energized electric lines without supervision from a qualified arborist. Reference: American National Standards Institute-ANSI Z133.1-2006: Section 4 Electrical Hazards, 4.2.3 Among other methods, one feasible and acceptable means of abatement to correct this hazard would be to have the arborist trainee cutting in the tree be under the direct on site supervision of a qualified arborist when they must approach closer than 10 feet of an energized conductor in excess of 750 volts. (b)Date of Violation:09/28/12 Location:Middle of the Back Yard at 19 Dixie Drive, Towson, Maryland Condition:The arborist trainee climber/cutter was felling branches/limbs with the possibility that the branches/limbs could contact the energized lines without a second qualified line clearance arborist or trainee being present. Reference: American National Standards Institute-ANSI Z133.1-2006: Section 4 Electrical Hazards, 4.2.4 Among other methods, one feasible and acceptable means of abatement to correct this hazard would be to have a second qualified arborist or trainee on site to afford constant verbal contact when branches/limbs are being felled which cannot be first cut to sufficiently clear the electrical conductors.
More inspections in this industry (NAICS 561730)
HELENDALE, CA—2026-07-17 00:00:00
IGNACIO PEREZ LANDSCAPE AND MAINTENANCE
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
NEW BOSTON, NH—2026-07-16 00:00:00
ANDREW GRANT'S TREE SERVICE
LAKE PARK, NC—2026-07-15 00:00:00
161553 - QUALITY ARBOR SERVICES INC.
SACRAMENTO, CA—2026-07-15 00:00:00
JOE'S LANDSCAPING & CONCRETE INC.
More inspections in MD
BALTIMORE, MD—2026-07-16 00:00:00
VAL CONSTRUCTION INC
CHESTERTOWN, MD—2026-07-15 00:00:00
WALLACE HENRY DISPOSAL, LLC
PARKVILLE, MD—2026-07-15 00:00:00
AMERICAN AUTOMATIC SPRINKLER COMPANY, INC.
PARKVILLE, MD—2026-07-15 00:00:00
THE POWER SOURCE, INC.
PARKVILLE, MD—2026-07-15 00:00:00
TEEL CONSTRUCTION, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316610427.