CONCORD, NC —
OSHA Inspection: MJC FRAMING CO INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of MJC FRAMING CO INC. in 378 GEORGE W. LILES PARKWAY, CONCORD, NC 28027 (NAICS 238130). OSHA activity number 316650514.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MJC FRAMING CO INC.
- Site address
- 378 GEORGE W. LILES PARKWAY
- City
- CONCORD
- State
- NC
- ZIP
- 28027
- Mailing
- 3315 BROOKTREE LANE, INDIAN TRAIL, NC 28079
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 8
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
4 citations on file for this inspection.
95012901
- Issued
- Nov 26, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall from elevation and struck-by hazards: a)jobsite, where, on July 25, 2012, metal plate connected wood trusses, 17 feet above the ground, were not adequately supported during installation because the third bearing support was missing due to the incomplete interior masonry wall. b)jobsite, where, on July 25, 2012, metal plate connected wood trusses, 17 feet above the ground, were installed without sufficient lateral restraint and diagonal bracing. Among other methods, one feasible and acceptable abatement method would be to follow the recommendations and guidelines for handling, installing, and bracing wood trusses of HIB-91 from the Truss Plate Institute and the booklet, "Building Component Safety Information -- Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses" (BCSI) jointly produced by the Structural Building Components Association and Truss Plate Institute.
1926.21 B02
- Issued
- Nov 26, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $2,100 · Current $2,100
1926.502 D15
- Issued
- Nov 26, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $2,100 · Current $2,100
1926.503 A01
- Issued
- Nov 26, 2012
- Abate by
- Nov 29, 2012
More inspections at MJC Framing CO INC.