WILMINGTON, NC —
OSHA Inspection: WILMINGTON ICE VENTURES, LLC DBA THE WILMINGTON IC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of WILMINGTON ICE VENTURES, LLC DBA THE WILMINGTON IC in 7201 OGDEN BUSINESS LN, WILMINGTON, NC 28411 (NAICS 713990). OSHA activity number 316779180.
Where did this inspection happen?
- Establishment
- WILMINGTON ICE VENTURES, LLC DBA THE WILMINGTON IC
- Site address
- 7201 OGDEN BUSINESS LN
- City
- WILMINGTON
- State
- NC
- ZIP
- 28411
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713990
- SIC code (legacy)
- 7999
- Employees
- 25
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
14 citations on file for this inspection.
95012901
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $1,000 · Current $700 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to Ammonia R-717: a)facility, machinery room - where the employer did not post emergency shutdown procedures for maintenance employees who conducted routine maintenance on the refrigeration system containing Ammonia R-717, and are subject to an uncontrolled release of this chemical. One feasible and acceptable abatement method, among others, to correct this hazard is the following: 1.Emergency shutdown procedures, including precautions to be observed in case of a breakdown or leak, shall be displayed on a conspicuous card located as near as possible to the refrigerant compressor. These precautions shall address: a)instructions for shutting down the system in case of emergency; b)the name, address, and day and night telephone numbers for obtaining service' and c)the names, addresses, and telephone numbers of all corporate, local, state, and federal agencies to be contacted as required in the event of a reportable incident. Reference: ANSI/ASHRAE Standard 15-2004, Safety Standard for Refrigeration Systems, Section 11.7. b)facility, machinery room - where the employer did not post the entrance to the refrigeration room prohibiting access by unauthorized personnel. One feasible and acceptable abatement, among others, to correct this hazard is: 1,At the entrance to each refrigeration machinery room, provide a legible permanent sign, securely attached and easily accessible, reading "Machinery Room - Authorized Personnel Only." The sign shall further communicate that entry is forbidden except by those personnel trained in the emergency procedures. Reference: ANSI/ASHRAE Standard 15-2004, Safety Standard for Refrigeration Systems, Section 11.2.4.
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.38 B
- Issued
- Nov 20, 2012
- Abate by
- Jan 4, 2013
- Penalty
- Initial $1,000 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.133 A01
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $1,000 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.132 D01
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.138 A
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $600 · Current $420 Reduced
Recent events (2)
- — I (S) $420.00
- — Z (S) $600.00
1910.147 C01
- Issued
- Nov 20, 2012
- Abate by
- Jan 4, 2013
- Penalty
- Initial $1,000 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.147 C04 I
- Issued
- Nov 20, 2012
- Abate by
- Jan 4, 2013
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C05 I
- Issued
- Nov 20, 2012
- Abate by
- Jan 4, 2013
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C07 I
- Issued
- Nov 20, 2012
- Abate by
- Dec 14, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $1,000 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.1200 E01
- Issued
- Nov 20, 2012
- Abate by
- Jan 4, 2013
- Penalty
- Initial $1,000 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.1200 G08
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H01
- Issued
- Nov 20, 2012
- Abate by
- Dec 14, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.37 B02
- Issued
- Nov 20, 2012
- Abate by
- Nov 23, 2012
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 713990)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316779180.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.