LAS VEGAS, NV —
OSHA Inspection: A2Z MOTOR SPORTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A2Z MOTOR SPORTS in 7060 WEST WARM SPRINGS ROAD, SUITE #130, LAS VEGAS, NV 89113 (NAICS 811198). OSHA activity number 316846054.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A2Z MOTOR SPORTS
- Site address
- 7060 WEST WARM SPRINGS ROAD, SUITE #130
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89113
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811198
- SIC code (legacy)
- 7549
- Employees
- 8
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
618037501
- Issued
- Sep 17, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
Nevada Revised Statute 618.375 Duties of employers. Every employer shall: 1. Furnish employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his or her employees. - In the workshop and storage area of A2Z Motorsports, located at 7060 West Warm Springs Road, Suite #130. Las Vegas, Nevada 89113. 1. On August 9, 2013, a racking system located near the East side of the establishments shop area was being used to store approximately twenty eight (28) scooters weighing approximately 250 LBS each. There were also approximately eight (8) pallets of miscellaneous helmets and parts being stored as well. The employer did not take the appropriate steps to insure the proper installation and use of the racking system as required by the ANSI MH16.1. 2. On August 9, 2013, a racking system located near the West side wall of the establishments shop area was being used to store approximately four (4) scooter weighing approximately 250 LBS each. There were also approximately three (3) pallets of helmets and one (1) pallet of motor oil stored on the racking system. The employer did not take the appropriate steps to insure the proper installation and use of the racking system as required by the ANSI MH16.1. Reference: ANSI MH16.1 - 2004(R2008) Specification for Design, Testing & Utilization of Industrial Steel Storage Racks. Section 1.4.2: Plaque. The owner is responsible for displaying in one for more conspicuous locations a permanent plaque(s). Each plaque shall have an area of not less that 50 square inches. Plaques shall show in clear, legible print (a) the maximum permissible unit load and/or maximum uniformly distributed load per level, (b) the average unit load if applicable and (c) maximum total load per bay. The employer did not ensured that the maximum load for the shelving units was legibly and conspicuously posted, leaving the potential for the shelves to become over loaded, which may cause them to collapse potentially leading to serious crushing injuries and/or death. Section 1.4.4: Load Application and Rack Configuration Drawings. Load applications and configuration drawings shall be furnished with each rack installation. One copy should be retained by the owner and another by the dealer or other local rack manufacturer representative for use by an inspecting body. Employer did not have a copy of the load application and configuration drawings, and could not provide them to the inspecting body; proper shelf configuration and/or loading could not be established. Section 1.4.7: Column Base Plates and Anchors. The bottom of all columns shall be furnished with column base plates, as specified in section 7.2. All rack columns shall be anchored to the floor with anchor bolts capable of resisting the forces caused by the horizontal and vertical loads on the rack. The racks had not been anchored to the concrete floor by means of the provided base plates. Forces exerted on the racks, eithervertical or horizontal, could cause the unit to tip, leading to sever crushing injuries and/or death. Section 7.1.2: Beam Locking Device. Except for movable-shelf racks, beams shall have connection locking devices (or bolts) capable of resisting an upward force of 1,000 pounds (453.6 kg) per connection without failure or disengagement. The racks had not been properly secured to the columns through means of locking devices or bolts capable of withstanding 1,000 pounds of upward force, leaving the possibility that the powered industrial truck may dislodge the rack. This could cause the rack to collapse, in part or in full, leading to serious crushing injuries and/or death. ONE POSSIBLE MEANS OF ABATEMENT WOULD BE TO FOLLOW THE DESIGN, INSTALLATION, AND UTILIZATION REQUIREMENTS SET FORTH IN ANSI MH16.1 - 2004(R2008).
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2000.00
1910.178 L02 II
- Issued
- Sep 17, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2000.00
More inspections at A2Z Motor Sports
View A2Z Motor Sports's full OSHA safety record →
More inspections in this industry (NAICS 811198)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316846054.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.