CHARLOTTE, NC —
OSHA Inspection: DISTINCTIVE CABINETS LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of DISTINCTIVE CABINETS LLC in 319 OLD HEBRON RD, CHARLOTTE, NC 28273 (NAICS 337110). OSHA activity number 317168664.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DISTINCTIVE CABINETS LLC
- Site address
- 319 OLD HEBRON RD
- City
- CHARLOTTE
- State
- NC
- ZIP
- 28273
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 2434
- Employees
- 12
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
13 citations on file for this inspection.
95012901
- Issued
- Aug 13, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $1,400 · Current $1,400
9210E200
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards: a)production area, employees in the production area were exposed to fire and explosion hazards in that the Kst of the wood dust was 14.8, and the dust was classified as Class II. b)production area - sliding saw, the ductwork was not connected to the dust collection system on or about July 9, 2013. c)production area, metal duct work was not used throughout the ventilation system. Nonmetallic duct was used throughout the facility. Reference NFPA 664 8.2.2.2.1.1. d)production area, the ductwork throughout the system was not grounded on or about May 14, 2013. Reference NFPA 664 8.2.2.2.1.8. e)production area, the metal ductwork that was used through the dust collection system including but not limited to the CNC Router was not equipped with a deflagration relief vents and vent duct designed, insalled, and maintained in accordance with NFPA 68. Reference NFPA 664 8.2.2.2.4. f)production area, compressed air that was used for cleaning was operating above 15 p.s.i. Reference NFPA 664 11.2.1.1(3). g)production area, prior to cleaning the area the wood dust was not vacuumed. Reference NFPA 664 11.21.1.1 (1). Abatement Note: Among others, one feasible and acceptable method of abating this violation will include but not be limited to ensuring that the ventilation systems are operating according to the manufacturer's specifications. The local ventilation systems flow rate and ductwork should be installed and operating in accordance with NFPA 664 "Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities." Additionally, a plan and schedule should be developed to provide regular and frequent cleanup to reduce dust accumulations.
1910.22 A01
- Issued
- Aug 13, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $100
9210E200
Recent events (2)
- — I (S)
- — Z (S) $100.00
1910.107 E02
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $100 · Current $100
1910.178 C02 VIA
- Issued
- Aug 13, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $100
Recent events (2)
- — I (S)
- — Z (S) $100.00
1910.242 B
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $100
Recent events (2)
- — I (O)
- — Z (S) $100.00
1910.304 G05
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $100 · Current $100
1910.305 G02 III
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $100 · Current $100
1910.307 C
- Issued
- Aug 13, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $1,400
9210E200
Recent events (2)
- — I (S)
- — Z (S) $1400.00
1910.1200 G08
- Issued
- Aug 13, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $1,400
Recent events (2)
- — I (O)
- — Z (S) $1400.00
1910.22 D01
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
1910.157 C01
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
1910.303 G01 I
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
1910.1200 F05 I
- Issued
- Aug 13, 2013
- Abate by
- Aug 16, 2013
More inspections at Distinctive Cabinets LLC
View Distinctive Cabinets LLC's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 317168664.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.