OSHA Inspection: UNITED EXTERIORS INC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of UNITED EXTERIORS INC in 1318 FOUR ORCHARD LANE, ODENTON, MD 21113 (NAICS 238160). OSHA activity number 317354439.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Exteriors INC — free Get an email when a new federal OSHA severe-injury report for United Exteriors INC is published. One employer, no account, unsubscribe in one click.
Site address
1318 FOUR ORCHARD LANE
City
ODENTON
State
MD
ZIP
21113
Mailing
2207 BEVERLY DRIVE, HAGERSTOWN, MD 21740
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
SIC code (legacy)
1761
Employees
4
Ownership type
A
Industry flags
Construction safety.

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 07 1 instance 3 exposed
Issued
Dec 26, 2013
Abate by
Jan 3, 2014
Penalty
Initial $1,050 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $1050.00

1926.501 A02

Serious Gravity 06 1 instance 1 exposed
Issued
Dec 26, 2013
Abate by
Jan 3, 2014
Penalty
Initial $1,400 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1400.00

1926.503 A01

Serious Gravity 07 1 instance 3 exposed
Issued
Dec 26, 2013
Abate by
Jan 28, 2014
Penalty
Initial $1,050 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $1050.00

50104 A

Serious Gravity 07 3 instances 3 exposed
Issued
Dec 26, 2013
Abate by
Jan 3, 2014
Penalty
Initial $1,050 · Current $525 Reduced
Labor and Employment Article, Section 5-104(a): The employer did not
furnish employment and a place of
employment which were free from recognized hazards that were causing or
likely to cause death or serious
physical harm to employees:
(a)Date of Violation:On or About 11/15/13
Location:Roof Peak of House
Condition:Employees installing the vapor barrier and shingles on a 7/12
sloped roof were
exposed to falls as great as 29 feet to ground when they utilized vertical
lifelines as
part of personal fall arrest systems that were tied and knotted around
anchors at the
peak of the roof.
(b)Date of Violation:On or About 11/18/13
Location:Roof Peak of House
Condition:An employee installing the vapor barrier and shingles on a 4/12
sloped roof was
exposed to falls as great as 15 feet to ground when he utilized a vertical
lifeline as part
of a personal fall arrest system that was tied and knotted around an
anchor at the peak
of the roof.
Among other methods, one feasible and acceptable method to correct the
hazard is to comply with
ANSI/ASSE A10.32-2004 Section 3 General Requirements: 3.7.3 Knots are not
allowed in lifelines, lanyards
or other direct-impact components.
Abatement documentation (photographs, receipts, copies of programs,
training certification, etc.)
is required for this item.
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $1050.00

1926.503 B01

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Dec 26, 2013
Abate by
Jan 28, 2014
Recent events (2)
  • — I (O)
  • — Z (O)