Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEP BOYS MANNY MOE & JACK OF CALIFORNIA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PEP BOYS MANNY MOE & JACK OF CALIFORNIA in 4141 NORTH RANCHO DRIVE, LAS VEGAS, NV 89130 (NAICS 811111). OSHA activity number 317369676.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PEP Boys Manny MOE & Jack of California — free Get an email when a new federal OSHA severe-injury report for PEP Boys Manny MOE & Jack of California is published. One employer, no account, unsubscribe in one click.
Site address
4141 NORTH RANCHO DRIVE
City
LAS VEGAS
State
NV
ZIP
89130
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
SIC code (legacy)
7538
Employees
31
Ownership type
A
Industry flags
Manufacturing safety.

4 citations on file for this inspection.

1910.305 G02 III

Repeat Gravity 01 1 instance 1 exposed
Issued
Jan 8, 2014
Abate by
Feb 10, 2014
Penalty
Initial $200 · Current $160 Reduced
Recent events (2)
  • — I (R) $160.00
  • — Z (R) $200.00

618037501

Serious Gravity 05 4 instances 5 exposed
Issued
Jan 8, 2014
Abate by
Feb 21, 2014
Penalty
Initial $5,000 · Current $4,000 Reduced
Nevada Revised Statute 618.375(1):  Duties of employers.  Every employer
shall furnish
employment and a place of employment which are free from recognized
hazards that are causing
or are likely to cause death or serious physical harm to his or her
employees.
At the Pep Boys shop (Store #868), employees performed repairs and
maintenance on
automotive vehicles as part of their job duties, which required the use of
vehicle lifts
(Wheeltronic Ltd. Alignment Rack Serial Number: S9-95400; Rotary two-post
vehicle
lift Model: SPOA10; Rotary in-ground hydraulic lift Model: SL210 and
SL212).   The
employer did not ensure vehicle lift inspections, maintenance, and
operator training were
implemented and maintained in accordance with ANSI/ALI ALOIM: 2008, which
exposed employees to caught in and struck by hazards.  The following are
instances in
which the employer did not meet the requirements set forth by ANSI/ALI
ALOIM: 2008
standards:
4.3 Operator Training.  The owner or employer shall appropriately document
operator training by completing the operator training log found in the
appendix
to this standard.
5.4 Qualified Inspection Documentation.  A record of each periodic
inspection
shall be prepared and maintained noting observations and findings of all
points
of inspection recommended by the manufacturer as well as subsequent
repairs or
replacements accomplished.
5.6.1 Inspection Points - Checklist.  The qualified lift inspector shall
follow the
specific directions provided by the lift manufacturer in the inspection of
each lift
including the following minimum points.  If a lift manufacturer supplied
checklist
is not readily available then the appropriate periodic inspection
checklist(s) located
in the appendix to this standard shall be used.  At the completion of the
inspection
the qualified lift inspector shall complete the inspection certificate
also located in
the appendix to this standard.  The qualified lift inspector shall obtain
the
acknowledgement signature of the owner or employer and post the inspection
certificate along with the inspection checklist on or near the lift
inspected or
together with other printed material or records pertaining to the lift.
6.1.1 Planned Maintenance Procedure.  The owner or employer shall
establish a
periodic planned maintenance procedure in accordance with the lift
manufacturer
in order to ensure reliability and allow the continued safe operation of
the lift.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHOD WOULD BE TO FOLLOW THE REQUIREMENTS OF THE ANSI/ALI
ALOIM: 2008 WITH REGARDS TO OPERATOR TRAINING, INSPECTION
DOCUMENTATION, AND PLANNED MAINTENANCE PROCEDURES.
Recent events (3)
  • — P (S) $4000.00
  • — I (S) $4000.00
  • — Z (S) $5000.00

1904.32 A01

Other-than-serious Gravity 03 2 instances 31 exposed
Issued
Jan 8, 2014
Abate by
Feb 21, 2014
Penalty
Initial $1,000
Recent events (3)
  • — P (O)
  • — I (O)
  • — Z (O) $1000.00

1904.32 B03

Other-than-serious Gravity 03 3 instances 31 exposed
Issued
Jan 8, 2014
Abate by
Feb 21, 2014
Penalty
Initial $1,000
Recent events (2)
  • — I (O)
  • — Z (O) $1000.00

View PEP Boys Manny MOE & Jack of California's full OSHA safety record →