Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: PURRFECT AUTO SERVICE #236

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PURRFECT AUTO SERVICE #236 in 5735 SOUTH DURANGO DRIVE, LAS VEGAS, NV 89113 (NAICS 811111). OSHA activity number 317369858.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Purrfect Auto Service #236 — free Get an email when a new federal OSHA severe-injury report for Purrfect Auto Service #236 is published. One employer, no account, unsubscribe in one click.
Site address
5735 SOUTH DURANGO DRIVE
City
LAS VEGAS
State
NV
ZIP
89113
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
SIC code (legacy)
7538
Employees
6
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

618037501

Deleted Serious Gravity 05 4 instances 2 exposed
Issued
Jan 21, 2014
Abate by
Feb 23, 2014
Penalty
Initial $2,000
Nevada Revised Statute 618.375(1): Duties of employers. Every employer
shall furnish
employment and a place of employment which are free from recognized
hazards that are causing
or are likely to cause death or serious physical harm to his or her
employees:
At the Purrfect Auto Shop #236, employees use seven automotive lifts to
make repairs
on standard and commercial vehicles; Forward brand (2) post lift, serial
#1070BKN29310, Hanmecson (2) post lift, serial # 05102151, Hanmecson (4)
post lift,
serial #04140217, Hanmecson (4) post lift, serial #04140226, Forward (2)
post lift, serial
107BKN, Hanmecson (4) post lift, serial #04140218 and a Ammco (2) post
lift, serial
#P000002270. Employee training and checklist records, equipment
maintenance and
documentation were not maintained in accordance with ANSI B 153.1/ALI
ALOIM:2008
nor the Hanmecson International, Inc Owner's Manual Standards. The ANSI/ALI
ALOIM:2008 Standards 4.3, 5.4, 5.6.1, and 6.1.1 require that the employer
adhere to
operator training, inspection documentation, inspection points checklists
and a planned
maintenance procedure.
4.3 Operator Training. The owner or employer shall appropriately document
operator
training by completing the operator training log found in the appendix to
this standard.
5.4 Qualified Inspection Documentation. A record of each periodic
inspection shall be
prepared and maintained noting the observations and findings of all points
of inspection
recommended by the manufacturer as well as subsequent repairs or
replacements
accomplished.
5.6.1 Inspection Points - Checklist. The qualified lift inspector shall
follow the specific
directions provided by the lift manufacturer in the inspection of each
lift including the
following minimum points. If a lift manufacturer supplied checklist is not
readily
available then the appropriate periodic inspection checklists(s) located
in the appendix to
this standard shall be used. At the completion of the inspection the
qualified lift inspector
shall complete the inspection certificate also located in the appendix to
this standard. The
qualified lift inspector shall obtain the acknowledgement signature of the
owner or
employer and post the inspection certificate along with the inspection
checklist on or near
the lift inspected or together with other printed material or records
pertaining to the lift.
6.1.1 Planned Maintenance Procedure. The owner or employer shall establish
a periodic
planned maintenance procedure in accordance with the recommendations of
the lift
manufacturer in order to ensure reliability and allow the continued safe
operation of the
lift.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHOD WOULD BE TO FOLLOW THE REQUIREMENTS OF THE ANSI/ALI
ALOIM: 2008 WITH REGARDS TO OPERATOR TRAINING, INSPECTION
DOCUMENTATION, INSPECTION POINTS CHECKLIST AND IMPLEMENTATION
OF A PLANNED MAINTENANCE PROCEDURE.E
Recent events (2)
  • — I (S)
  • — Z (S) $2000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 317369858.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.