LAS VEGAS, NV ·
OSHA Inspection: LLANTERA TROPICANA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LLANTERA TROPICANA in 1250 EAST TROPICANA AVENUE, LAS VEGAS, NV 89119 (NAICS 811118). OSHA activity number 317370385.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LLANTERA TROPICANA
- Site address
- 1250 EAST TROPICANA AVENUE
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89119
- Mailing
- 1250 EAST TROPICANA AVENUE, LAS VEGAS, NV 89119
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811118
- SIC code (legacy)
- 7539
- Employees
- 10
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
12 citations on file for this inspection.
618037501
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
Nevada Revised Statute 618.375(1): Duties of employers. Every employer shall fur nish employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his o r her employees. Within the maintenance area at the Llantera Tropicana workplace , employees were exposed to the recognized hazard of crushing as a result of byp assing the safety locks on automotive lifts in two instances. 1) All four air lo cks were disengaged on one of the lifts (make: Rotary Lift, model: SM123-10, ser ial number: JCY03D0005, lifting capacity: 12,000 pounds). Employees were using a n air valve to lower the lift instead of a push button switch. The push button s witch disengages the air locks in order to lower the lift, which resulted in byp assing the safety locks. These deficiencies exposed employees to possible crushi ng hazards as a result of the lift being fully lowered and bypassing the safety locks. 2) Another lift (make: Bend Pac, Inc., model: HD 0-12LSX-B, serial number: 6026, lifting capacity: 12,000 pounds) that was being used had a screwdriver holding the secondary lock. If one of the cables were to break, the secondary lock would not allow the safety lock to engage. Two of the cables for the lift were raised approximately 8-10 inches above the columns. The cables are intended to be raised up to four inches above the column in order to prevent friction amongst the cables, which could cause the cables to fray and b reak. An air valve was also being used on this lift instead of a push button swi tch, which resulted in bypassing the safety locks. These deficiencies exposed em ployees to possible crushing hazards as a result of the lift being fully lowered and bypassing the safety locks, and if any of the cables were to break. Reference: American National Standards Institute (ANSI): ANSI/ALI ALOIM- 2000: S afety Requirements for Operation, Inspection and Maintenance: - Paragraph 4.4.4 (Operator Responsibilities): The lift owner or employer shall take all appropria te steps to follow the recommended inspection procedures of the lift manufacture r, but in no event shall the lift operator fail to inspect or take notice of the following features on a daily basis: (1) Accessibility and readability of the o perating procedures, safety tips and generic safety material; (4) Proper operati on of the lift controls, restraints and locking devices. - Paragraph 5.5: Qualif ied Inspection Frequency. Inspections by the owner or employer shall follow the recommendations of the lift manufacturer as to frequency. Without regard to the frequency of inspection specified by the lift manufacturer, whether it be weekly ,monthly, semi-annually, annually or on some other basis, the owner or employer shall ensure that the points presented in 5.6 are inspected by a qualified lift inspector as a minimum annual requirement. - Paragraph 6.2.1: Repair Maintenance Procedure. The owner or employer shall per form repair maintenance procedures whenever they are called for by the lift oper ator, qualified lift inspector or preventive maintenance technician. Repair main tenance shall be performed in accordance with the recommendations of the lift ma nufacturer in order to ensure reliability and allow the continued safe operation of the lift. One feasible and acceptable means of abatement is to follow the re quirements of ANSI/ALI ALOIM-2000, and ensure that both lifts are inspected and certified for use at least annually by a qualified person.ed
1910.215 A02
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $1,200 · Current $1,200
1910.215 A04
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $0 · Current $0
1910.303 B02
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $1,020 · Current $1,020
1910.304 B04
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $0 · Current $0
1910.304 G05
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $1,200 · Current $1,200
1910.305 B02 I
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $1,200 · Current $1,200
1910.305 G02 II
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $1,020 · Current $1,020
1910.157 C01
- Issued
- Mar 7, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $0 · Current $0
1910.1200 E01
- Issued
- Mar 7, 2014
- Abate by
- Mar 25, 2014
- Penalty
- Initial $0 · Current $0
1910.1200 G08
- Issued
- Mar 7, 2014
- Abate by
- Mar 25, 2014
- Penalty
- Initial $0 · Current $0
1910.1200 H01
- Issued
- Mar 7, 2014
- Abate by
- Mar 25, 2014
- Penalty
- Initial $0 · Current $0
More inspections at Llantera Tropicana
View Llantera Tropicana's full OSHA safety record →
More inspections in this industry (NAICS 811118)
More inspections in NV
Source