HENDERSON, NV ·
OSHA Inspection: ALL FOREIGN AUTO PARTS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALL FOREIGN AUTO PARTS INC. in 651 WEST SUNSET ROAD, HENDERSON, NV 89011 (NAICS 811111). OSHA activity number 317376051.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL FOREIGN AUTO PARTS INC.
- Site address
- 651 WEST SUNSET ROAD
- City
- HENDERSON
- State
- NV
- ZIP
- 89011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 8
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
618037501
- Issued
- Jul 28, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
Nevada Revised Statute 618.375(1): Duties of employers. Every employer shall furnish employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his or her employees: Five storage racks located in the warehouse were used to store automotive parts and were not secured to the floor of the building to prevent them from falling. This exposed employees to possible crushing injuries should the steel storage rack system tip over and land on the employees. Reference ANSI MH 16.1 Specification for Design, Testing, and Utilization of Industrial Steel Storage Racks. Section 1.4.7. Column Base Plates and Anchors. The bottom of all columns shall be furnished with column base plates, as specified in Section 7.2. All rack column shall be anchored to the floor with anchor bolts capable of resisting the forces caused by the horizontal and vertical loads on the rack. One feasible means of abatement would be to follow ANSI MH 16.1 Paragraph 1.4.7 (anchoring down rack).ring
More inspections in this industry (NAICS 811111)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 317376051.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.