BOISE, ID —
OSHA Inspection: CAFCO, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CAFCO, LLC in 1016 CAMERON, BOISE, ID 83709 (NAICS 236115). OSHA activity number 330017534.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAFCO, LLC
- Site address
- 1016 CAMERON
- City
- BOISE
- State
- ID
- ZIP
- 83709
- Mailing
- 5021 SORRENTO DRIVE, BOISE, ID 83704
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 C02
- Issued
- Mar 25, 2011
- Abate by
- Mar 28, 2011
- Penalty
- Initial $4,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite: On March 18, 2011 and times prior thereto, employees worked in a trench that was estimated to be 40 to 50 feet long and, approximately eight to ten feet deep with a single ladder located at the rear of the trench.
Recent events (3)
- — F (S) $1000
- — C (S) $4200
- — Z (S) $4200
1926.651 I03
- Issued
- Mar 25, 2011
- Abate by
- Mar 28, 2011
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: a)Jobsite: On March 18, 2011 and times prior thereto a support system was not in place for the rear patio structure where the area had been excavated, exposing employees working in that area to a potential collapse of the structure.
Recent events (3)
- — F (S) $0
- — C (S) $2400
- — Z (S) $2400
1926.651 J02
- Issued
- Mar 25, 2011
- Abate by
- Mar 28, 2011
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a)Jobsite: On March 17, 2011 and times prior thereto employees working in the trench were exposed to the hazard of having the excavated materials (spoil piles) placed on or near the edge of the excavation. b) Jobsite: On March 18, 2011 employees working within a timber shoring system, were exposed to the hazard of excavated materials where at least two feet of the excavated walls on either side were not supported or shielded.
Recent events (3)
- — F (S) $0
- — C (S) $4200
- — Z (S) $4200
1926.651 K01
- Issued
- Mar 25, 2011
- Abate by
- Mar 28, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: a) Jobsite: On March 17, 2011 and times prior thereto, a competent person did not conduct an inspection of a trench which measured approximately seven to ten feet deep, four to six feet across, and had vertical walls, to determine the proper protective system needed prior to allowing employees to enter the trench and perform work activities which included, but were not limited to digging for sewer and water lines. b) Jobsite: On March 18, 2011 a competent person did not conduct an inspection of a timber shoring system to ensure the system shielded or supported the excavated vertical sides of the trench prior to allowing employees to enter and perform work within the trench and shoring system.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Mar 25, 2011
- Abate by
- Mar 28, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) Jobsite: On March 17, 2011 and times prior thereto, a means of protection was not in place prior to allowing employees to enter a trench which measured approximately eight to ten feet deep, with vertical sides and perform activities which included but were not limited to digging for water and sewer lines. b) Jobsite: On March 18, 2011 employees were allowed to enter and perform work within a timber shoring system which did not shield or support at least two feet of the vertical trench on both sides.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236115)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330017534.