CRESTED BUTTE, CO —
OSHA Inspection: CRESTED BUTTE, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CRESTED BUTTE, LLC in 12 SNOWMASS ROAD, CRESTED BUTTE, CO 81225 (NAICS 713990). OSHA activity number 330291832.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRESTED BUTTE, LLC
- Site address
- 12 SNOWMASS ROAD
- City
- CRESTED BUTTE
- State
- CO
- ZIP
- 81225
- Mailing
- P.O. BOX 5700, CRESTED BUTTE, CO 81224
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713990
- Employees
- 150
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 4, 2011
- Abate by
- Sep 15, 2011
- Penalty
- Initial $4,950 · Current $2,465 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to impact injuries: a) On or about April 13, 2011 and times prior, press operators were using dies that were not tested and rated to identify their tonnage and safe compression loading. American National Standards Institute (ANSI) B11.2-1982, paragraph 6.2(1) states: "All dies shall be: (1) Identified with the tonnage and, if necessary, stroke requirements; and/or those characteristics shall be recorded and available to the die setter". The dies were shop made and the employer was not able to determine the load that could safely be applied to the die exposing the press operator to serious injuries in the event of the failure of the die from overloading the die. Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (S) $2465
- — Z (S) $4950
5(a)(1)
- Issued
- Aug 4, 2011
- Abate by
- Sep 15, 2011
- Penalty
- Initial $4,950 · Current $2,465 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to crushing injuries: a) On or about April 13, 2011 and times prior, the loading area overheard door was not equipped with doorstops, exposing employees to the hazard of being crushed or struck by the door. Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (S) $2465
- — Z (S) $4950
1910.23 C01
- Issued
- Aug 4, 2011
- Abate by
- Sep 15, 2011
- Penalty
- Initial $4,950 · Current $2,465 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) On or about April 13, 2011 and times prior, employees were exposed to injuries from falls to the lower surface. No protective guardrail system had been installed where employees access the air handler platform located in Elevation Hotel loading dock area. Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (S) $2465
- — Z (S) $4950
1910.178 A04
- Issued
- Aug 4, 2011
- Penalty
- Initial $4,208 · Current $2,790 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions, which affect capacity and safe operation, shall not be performed by the customer or user without manufacturers prior written approval. Capacity operation, and maintenance instruction plates, tags, or decals shall be changed accordingly: On or about April 13, 2011 and times prior, employees were exposed to injuries in that, a snowcat push/pull device which slid over the forks of the caterpillar 430 forklift was designed and used without the Caterpillar 430 forklift manufacturer's prior approval.
Recent events (2)
- — I (O) $2790
- — Z (S) $4207.5
1910.212 A01
- Issued
- Aug 4, 2011
- Penalty
- Initial $2,525 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operators and other employees from hazards created by the flying chips: a) On or about April 13, 2011 and times prior, employees were exposed to injuries while working in the shop. The drill press rotating chuck was not guarded exposing employees to being struck by hot waste materials.
Recent events (2)
- — I (O) $2000
- — Z (S) $2524.5
1910.215 A04
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: a) On or about April 13, 2011 and times prior, employees were exposed to injuries in that, the bench grinder work rest was not adjusted to a maximum opening of one-eighth inch.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.215 B09
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel peripheries and the adjustable tongue or the end of the safety guard periphery member at the top exceeded one-fourth inch: On or about April 13, 2011 and times prior, employees were exposed to injuries from being struck by the grinding wheel in the event of it fracturing.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.212 B
- Issued
- Aug 4, 2011
- Penalty
- Initial $2,525 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving: a) On or about April 13, 2011 and times prior, employees were exposed to injuries in that, equipment located at the following locations had not been anchored: 1) Truck shop, two wheel balancing units; 2) Lift shop, bench grinder; 3) Carpenter shop, band saw.
Recent events (2)
- — I (O) $2000
- — Z (S) $2524.5
1910.219 D01
- Issued
- Aug 4, 2011
- Penalty
- Initial $2,525 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys, any part of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: a) On or about April 13, 2011 and times prior, employees were exposed to injuries in that, a band saw lower pulley was not guarded. The band saw was located in the carpenter shop.
Recent events (2)
- — I (O) $2000
- — Z (S) $2524.5
1910.243 C01
- Issued
- Aug 4, 2011
- Penalty
- Initial $2,525 · Current $0 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheels were used on portable grinders which were not provided with safety guards meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4): a) On or about April 13, 2011 and times prior, employees were exposed to injuries in that, the rotating abrasive wheel a part of the portable grinder was not guarded. The portable grinder is located in the truck shop.
Recent events (2)
- — I (S) $0
- — Z (S) $2524.5
1910.305 B02 I
- Issued
- Aug 4, 2011
- Penalty
- Initial $4,208 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fitting shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear: a) On or about April 13, 2011 and times prior, employees were exposed to electrical shock from open faceplates at the following locations: 1) Lodge at Mountaineer Square, 110-volt exposed conductors; 2) Grand Lodge electrical room that was not restricted, 110-volt exposed conductors; 3) Elevation Hotel electrical room that was not restricted, 480-volt buss bars were exposed; 4) Elevation Hotel top floor electrical room that was not restricted, 240-volt cardboard used as cover plate.
Recent events (2)
- — I (S) $2000
- — Z (S) $4207.5
1910.305 B01
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed: a) On or about April 13, 2011 and times prior, employees were exposed to injuries in that, the conduit supplying power to the air handler was separated exposing the 110-volt conductors to abrasion. The conduit was located on the west side of the roof of the Grand Lodge.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 E01
- Issued
- Aug 4, 2011
- Abate by
- Sep 15, 2011
- Penalty
- Initial $4,950 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: a) On or about April 13, 2011 and times prior, employees were exposed to electrical shock injury in that, 110-volt boxes (receptacles) were not approved for wet applications. The 110-volt receptacles were plugged into the snow cat heaters. The snow cats were located outside in the wet weather (snow). Another location where the 110-volt receptacles were in use was the ski school area. Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (O) $3000
- — Z (S) $4950
1910.134 F02
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employees using a tight fitting facepiece respirator were not fit tested prior to initial use of the respirator, and at least annually thereafter: a) On or about April 13, 2011 and times prior, employees were exposed to illnesses in that, the employees were required to wear half face respirators prior to being fit tested.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 I
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about April 13, 2011 and times prior, employees were exposed to injury/illness in that, a plastic container containing Citrus Degreaser located in the Silver Queen drive area was not labeled as to its contents.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 II
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) On or about April 13, 2011 and times prior, employees were exposed to injury/illness in that, a plastic container containing Citrus Degreaser located in the Silver Queen drive area was not labeled as to its hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) On or about April 13, 2011 and times prior, employees were exposed to electrical shock in that, a drop cord had a defective strain relief. The drop cord was located in the northeast area of the truck shop.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Crested Butte, LLC
View Crested Butte, LLC's full OSHA safety record →
More inspections in this industry (NAICS 713990)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330291832.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.