Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SNYDER'S DENT SHOP, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SNYDER'S DENT SHOP, INC. in HWY 2 & 1ST ST. W, CHESTER, MT 59522 (NAICS 811121). OSHA activity number 330291915.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Snyder'S Dent Shop, INC. — free Get an email when a new federal OSHA severe-injury report for Snyder'S Dent Shop, INC. is published. One employer, no account, unsubscribe in one click.
Site address
HWY 2 & 1ST ST. W
City
CHESTER
State
MT
ZIP
59522
Mailing
PO BOX 281, CHESTER, MT 59522
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
4
Ownership type
A

7 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 3 exposed
Issued
May 5, 2011
Abate by
May 12, 2011
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.24(h):     Standard railings were not provided on the open sides of all exposed stairways and stair platforms:
Recent events (2)
  • — I (S) $765
  • — Z (S) $1530

1910.107 B10

Serious Gravity 1 1 instance 1 exposed
Issued
May 5, 2011
Abate by
May 12, 2011
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.107(b)(10):     When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels did not effectively isolate the spraying area from the area in which the lighting unit was located, and were not so protected that breakage would be unlikely.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1530

1910.212 A01

Serious Gravity 1 1 instance 3 exposed
Issued
May 5, 2011
Abate by
May 16, 2011
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1530

1910.215 A04

Serious Gravity 1 1 instance 3 exposed
Issued
May 5, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 2 instances 3 exposed
Issued
May 5, 2011
Abate by
May 12, 2011
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i).
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
May 5, 2011
Abate by
May 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and cables were used as a substitute for the fixed wiring of a structure
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
May 5, 2011
Abate by
May 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):     The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330291915.