CANON CITY, CO —
OSHA Inspection: COLORADO HAZARD CONTROL, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of COLORADO HAZARD CONTROL, LLC in 615 MACON AVENUE, CANON CITY, CO 81212 (NAICS 562910). OSHA activity number 330293093.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLORADO HAZARD CONTROL, LLC
- Site address
- 615 MACON AVENUE
- City
- CANON CITY
- State
- CO
- ZIP
- 81212
- Mailing
- 2727 W. 92 AVENUE SUITE 10, DENVER, CO 80260
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1101 F02 I
- Issued
- Jun 15, 2011
- Abate by
- Jun 16, 2011
- Penalty
- Initial $2,550 · Current $2,040 Reduced
General-duty citation text
29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation: a) On or about April 19, 2011, and at times prior, employees were exposed to unknown quantities of airborne asbestos fibers while removing Class I asbestos containing materials because the employer had failed to perform an initial exposure assessment at or before the commencement of abatement activities.
Recent events (2)
- — I (O) $2040
- — Z (S) $2550
1926.1101 H03 IV A
- Issued
- Jun 15, 2011
- Abate by
- Jun 16, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
1926.1101(h)(3)(iv)(A): A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA): a) On or about April 19, 2011, and at times prior, the employer did not provide employees performing Class I asbestos abatement work inside of a regulated area (containment area) with a full-face powered air-purifying respirator or a supplied air respirator. Employees had performed removal and cleanup of textured ceiling covering (5-6% asbestos) while wearing standard full-face and half-face air-purifying respirators. An exposure assessment had not been conducted for these employees when work began on April 12, 2011, and was not used as the basis for respirator selection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Colorado Hazard Control, LLC