Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: Q3 CONTRACTING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of Q3 CONTRACTING, INC. in JEWELL AVE. AND LAFAYETTE ST., DENVER, CO 80210 (NAICS 237120). OSHA activity number 330294356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Q3 Contracting, INC. — free Get an email when a new federal OSHA severe-injury report for Q3 Contracting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
JEWELL AVE. AND LAFAYETTE ST.
City
DENVER
State
CO
ZIP
80210
Mailing
5300 COLORADO BLVD. BETWEEN SHERMAN AND EMERSON, DENVER, CO 80203
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
40
Ownership type
A

2 citations on file for this inspection.

1926.200 G02

Deleted Serious Gravity 5 5 exposed
Issued
Jun 7, 2011
Abate by
Jun 17, 2011
Penalty
Initial $3,443 · Current $0 Reduced
29 CFR 1926.200(g)(2):  The employer did not ensure that all traffic control signs or devices used for protection of construction workers conformed to Part VI of the Manual on Uniform Traffic Control Devices (MUTCD) Millennium Edition, December 2000:         a)  Q3 Contracting, Inc. at Jewell Ave. and Lafayette St., Denver, CO 80201:  On or before April 26, 2011, the employer did not ensure that warning signs conformed to the MUTCD in that employees had dug a trench near the middle of the intersection of Jewell Ave. and Lafayette Street, and no advanced warning signs were in place on the north and south sides of Lafayette Street, nor on the east side of Jewell Avenue.  In addition, access to Jewell Avenue was closed off at Humbolt Street, and there were no advanced warning signs on the north and south sides of Humbolt Street.  Finally, the east-bound access to Jewell was closed off at Downing Street, and there were no advanced warning signs on the north and south sides of Downing Street.  Employees were drilling a new natural gas pipeline, with this segment about 400 feet long.  Condition exposed employees to struck-by hazards.    Abatement note:  Abatement certification is required for this item (see enclosed, "Sample Abatement-Certification Letter").    Abatement note:  The MUTCD Section 6B.01 provides that the control of road users through a temporary traffic control zone shall be an essential part of highway construction, utility work, maintenance operations, and incident management.  Sections 6C.03 and 6C.04 discuss the requirements associated with advanced warning areas, providing that the advanced warning area is that section of the road where users are informed about the upcoming work zone or incident area.  Typical Applications 18 illustrates a Lane Closure for a Minor Street, applicable to Lafayette Street and Jewell Avenue.  Typical Application 20 illustrates a Detour for a Closed Street, and is applicable for the other intersections involving the closure of Jewell Avenue.
Recent events (3)
  • — J (S) $0
  • — C (S) $3442.5
  • — Z (S) $3442.5

1926.202

Deleted Serious Gravity 5 5 instances 1 exposed
Issued
Jun 7, 2011
Abate by
Jun 17, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.202:  The employer did not ensure that all barricades used for protection of construction workers conformed to Part VI of the Manual on Uniform Traffic Control Devices (MUTCD) Millennium Edition, December 2000:         a)  Q3 Contracting, Inc. at Jewell Ave. and Lafayette St., Denver, CO 80201:  On or before April 26, 2011, the employer did not ensure that the barricades conformed to the MUTCD in that employees had dug a trench near the middle of the intersection of Jewell Ave. and Lafayette Street, and no tapers was in place for southbound traffic entering the instersection on Lafayette Street.  In addition, the cone set next to the front fender of the truck for northbound traffic on Lafayette did not protect employees working in the bed of the truck and behind the truck.  There was no additional taper in front of the truck.  Condition exposed employees to struck-by hazards.    Abatement note:  Abatement certification is required for this item (see enclosed, "Sample Abatement-Certification Letter").    Abatement note:  The MUTCD Section 6C.08 discusses the requirements associated with temporary traffic control zones, including the use of tapers with channelizing devices to move traffic out of or into normal paths.  Section 6F.55 describes the use of cones and other barricades to serve as channelizing devices.  Typical Applications 18 illustrates a Lane Closure for a Minor Street, applicable to Lafayette Street and Jewell Avenue.  Typical Application 20 illustrates a a Detour for a Closed Street, applicable to Jewell Avenue.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View Q3 Contracting, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330294356.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.