CANTON, SD —
OSHA Inspection: ADAMS THERMAL SYSTEMS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ADAMS THERMAL SYSTEMS in 47920 FIFTH STREET, CANTON, SD 57013 (NAICS 333415). OSHA activity number 330294737.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADAMS THERMAL SYSTEMS
- Site address
- 47920 FIFTH STREET
- City
- CANTON
- State
- SD
- ZIP
- 57013
- Mailing
- 47920 FIFTH STREET, CANTON, SD 57013
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 623
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 17, 2011
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to a potential crushing and/or amputation hazard: (a) At Adams Thermal Systems located in Canton, SD, where, on or about 03/24/11, an employee was exposed to a potential crushing and/or amputation hazard while operating the Niagra N120-8-10 press brake, serial #43456. Among other methods, one feasible and acceptable abatement method to correct this hazard is to adhere to the requirments of ANSI B11.2-1995 Hydraulic Power Presses - Safety Requirements for Construction, Care, and Use: Section 6.3.3 Control Reliabilty: paragraphs 1, 2, and 3.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
More inspections at Adams Thermal Systems
View Adams Thermal Systems's full OSHA safety record →