Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRECISION FRAMING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECISION FRAMING, INC. in 3903 GLOBE THEATER AVENUE, BOISE, ID 83702 (NAICS 238130). OSHA activity number 330296088.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Precision Framing, INC. — free Get an email when a new federal OSHA severe-injury report for Precision Framing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3903 GLOBE THEATER AVENUE
City
BOISE
State
ID
ZIP
83702
Mailing
9169 KESTRAL FORK, MIDDLETON, ID 83644
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Other-than-serious 2 instances 1 exposed
Issued
Jul 13, 2011
Penalty
Initial $2,380 · Current $2,000 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    a) Southwest roof hip and roof trusses at 2nd level; On or about 5/20/11 and at times prior thereto, three employees tying the trusses together at the hip were inbetween the trusses and/or up on the truss top cord without a means of fall protection.    b) West side of structure at transition area of 1st to 2nd story; On or about 5/20/11 and at times prior thereto, an employee installing/nailing wall sheathing was working from the top of the exterior wall.    Note: Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $2380

1926.1053 B05 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).       a) West side of structure at transition area of 1st to 2nd story; On or about 5/20/11 and at times prior thereto, an employee installing/nailing wall sheathing was working from an extension ladder placed in a 60 degree angle.    Note: Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Precision Framing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330296088.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.