BOISE, ID —
OSHA Inspection: PRECISION FRAMING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRECISION FRAMING, INC. in 3903 GLOBE THEATER AVENUE, BOISE, ID 83702 (NAICS 238130). OSHA activity number 330296088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRECISION FRAMING, INC.
- Site address
- 3903 GLOBE THEATER AVENUE
- City
- BOISE
- State
- ID
- ZIP
- 83702
- Mailing
- 9169 KESTRAL FORK, MIDDLETON, ID 83644
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 13, 2011
- Penalty
- Initial $2,380 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Southwest roof hip and roof trusses at 2nd level; On or about 5/20/11 and at times prior thereto, three employees tying the trusses together at the hip were inbetween the trusses and/or up on the truss top cord without a means of fall protection. b) West side of structure at transition area of 1st to 2nd story; On or about 5/20/11 and at times prior thereto, an employee installing/nailing wall sheathing was working from the top of the exterior wall. Note: Abatement certification is NOT required for this item.
Recent events (2)
- — I (O) $2000
- — Z (S) $2380
1926.1053 B05 I
- Issued
- Jul 13, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). a) West side of structure at transition area of 1st to 2nd story; On or about 5/20/11 and at times prior thereto, an employee installing/nailing wall sheathing was working from an extension ladder placed in a 60 degree angle. Note: Abatement certification is NOT required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Precision Framing, INC.
View Precision Framing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330296088.