HOMEDALE, ID ·
OSHA Inspection: SPECIALTY INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPECIALTY INCORPORATED in 4323 PIONEER RD., HOMEDALE, ID 83628 (NAICS 321999). OSHA activity number 330296468.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECIALTY INCORPORATED
- Site address
- 4323 PIONEER RD.
- City
- HOMEDALE
- State
- ID
- ZIP
- 83628
- Mailing
- 4323 PIONEER RD., HOMEDALE, ID 83628
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 55
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.213 I01
- Issued
- Aug 1, 2011
- Abate by
- Aug 8, 2011
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: a) Resaw machine: On July 26, 2011 and times prior thereto the operator(s) of the Go Fast re-saw machine were exposed to the hazard of a six inch area of the band saw blade that was not guarded. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.219 C04 I
- Issued
- Aug 1, 2011
- Abate by
- Aug 8, 2011
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Resaw machine: On July 26, 2011 and times prior thereto employee(s) operating the resaw machine were exposed to two rotating shafts which measured approximately one inch in diameter and approximately one inch long. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (S) $892.5
- · Z (S) $1785
1904.29 B01
- Issued
- Aug 1, 2011
- Abate by
- Aug 2, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail as required by the regulation: a) The 2011 calendar year OSHA 300 log showed an injury resulting in days away from work classified as a job transfer or restriicted injury, per 29 CFR 1904.7(b)(4). b) The 2010 calendar year OSHA 300 log did not show the classification for each injury based on the most serious outcome for each case, per 29 CFR 1904.7(b)(4). Note) Abatement certification is required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1904.32 B03
- Issued
- Aug 1, 2011
- Abate by
- Aug 2, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(b)(3): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) was not properly certified: a) The OSHA 300A for calendar year 2010 was not certified by the highest company executive in the establishment or at the corporate level. b) The OSHA 300A for calendar year 2009 was not certified by the highest company executive in the establishment or at the corporate level. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B01 II
- Issued
- Aug 1, 2011
- Abate by
- Aug 2, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) Building one, manual pallet build-up area: On May 18, 2011 and times prior thereto, an electrical receptacle was missing half of the faceplate. Note) Abatement certification IS required for this item.
Recent events (2)