ARVADA, CO —
OSHA Inspection: MARK VII EQUIPMENT INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MARK VII EQUIPMENT INC. in 5981 TENNYSON ST, ARVADA, CO 80003 (NAICS 333319). OSHA activity number 330630328.
Where did this inspection happen?
- Establishment
- MARK VII EQUIPMENT INC.
- Site address
- 5981 TENNYSON ST
- City
- ARVADA
- State
- CO
- ZIP
- 80003
- Mailing
- 5981 TENNYSON ST, ARVADA, CO 80003
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333319
- Employees
- 90
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $4250.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: a) Mark VII Equipment, Inc. at 5981 Tennyson Street, Arvada, CO 80003: On or before 6/7/11, the employer did not ensure that the following machinery was guarded at the points of operation: 1) The Omada 125 press brake, model 12536, serial number 1250131, was not guarded around its point of operation, including the front and the back; 2) The Omada 80 press brake, model 80, serial number 811308, was not guarded around its point of operation, including the front and the back; 3) The Omada shear, model H3013, was not guarded behind the point of operation; and 4) The Omada laser, model AF4000E, was not guarded around the perimeter of the material bed. Conditions exposed employees to amputation hazards. Abatement note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter. Abatement note: To guard the rear of the press brakes and the shear, prevent employee access while the machines are in operation via a barrier, along with appropriate employee training and enforcement. To guard the perimeter of the laser bed, expanded metal should be a viable option.
Recent events (2)
- — I (S) $2125
- — Z (S) $4250
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $4250.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Mark VII Equipment, Inc. at 5981 Tennyson Street, Arvada, CO 80003: On or before 6/7/11, the employer did not develop, document, and utilize specific lockout tagout procedures for the following equipment: 1) The Omada 125 press brake, model 12536, serial number 1250131; 2) The Omada 80 press brake, model 80, serial number 811308; 3) The Omada shear, model H3013; and 4) The Omada laser, model AF4000E. Conditions exposed employees to amputation hazards. Abatement note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter. Abatement note: 1910.147(c)(4)(ii) provides that the procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized in the control of hazardous energy, and the means to enforce compliance.
Recent events (2)
- — I (S) $2125
- — Z (S) $4250
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Mark VII Equipment, Inc. at 5981 Tennyson Street, Arvada, CO 80003: On or before 6/7/11, the employer did not conduct a periodic inspection of the lockout tagout procedures at least annually. Conditions exposed employees to amputation hazards. Abatement note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter. Abatement note: 1910.147(c)(6)(ii) provides that the employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls was acquired by employees: a) Mark VII Equipment, Inc. at 5981 Tennyson Street, Arvada, CO 80003: On or before 6/7/11, the employer did not provide training to employees to ensure they understand the energy control program. Conditions exposed employees to amputation hazards. Abatement note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter. Abatement note: 1910.147(c)(7)(iv) provides that the employer shall certify that the employee training has been accomplished and was being kept up to date. The certification shall contain each employee's name and dates of training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 A01
- Issued
- Abate by
- Penalty
- Initial $850.00 · Current $425.00 Reduced
General-duty citation text
29 CFR 1904.32(a)(1): The employer did not review the OSHA 300 Log to verify that the entries were complete and accurate, and correct any deficiencies identified: a) Mark VII Equipment, Inc. at 5981 Tennyson Street, Arvada, CO 80003: On or before 6/7/11, the employer did not review the OSHA 300 Logs for the years 2008, 2009, 2010, and 2011, and correct any deficiencies. Some injuries that were recorded were not classified as Days Away from Work (Column H), Job Transfer or Restriction (Column I), or as Other Recordable Cases (Column J). Condition resulted in unclear reporting, classifying, and summarizing injuries. Abatement note: Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter. Abatement note: 1904.32(a)(3) provides that the employer shall certify the summary.
Recent events (2)
- — I (O) $425
- — Z (O) $850
More inspections in this industry (NAICS 333319)
DURHAM, NC—2026-06-09 00:00:00
161336 - HYDRO SERVICE - SUPPLIES, INC.
PEQUOT LAKES, MN—2026-05-27 00:00:00
111330 - HYBRID LIGHT SOLUTIONS LLC
MADRAS, OR—2026-04-24 00:00:00
317743831 - KEITH MANUFACTURING CO
DANVILLE, KY—2026-02-25 00:00:00
68888 - ITW FOOD EQUIPMENT GROUP LLC
BELLINGHAM, WA—2025-11-06 00:00:00
WA317988600 - CLARUS FLUID INTELLIGENCE LLC
More inspections in CO
BROOMFIELD, CO—2026-07-16 00:00:00
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15 00:00:00
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15 00:00:00
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15 00:00:00
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330630328.