OSHA Inspection: BELL PLUMBING AND HEATING CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BELL PLUMBING AND HEATING CO. in 1378 FOREST ST, DENVER, CO 80220 (NAICS 238220). OSHA activity number 330630542.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bell Plumbing and Heating CO. for free Get an email when a new federal OSHA severe-injury report for Bell Plumbing and Heating CO. is published. One employer, no account, unsubscribe in one click.
Site address
1378 FOREST ST
City
DENVER
State
CO
ZIP
80220
Mailing
2150 S ABILINE ST, AURORA, CO 80014
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 1, 2011
Abate by
Sep 22, 2011
Penalty
Initial $2,975 · Current $2,975
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c):\\r\\n(a)  Bell Plumbing and Heating Co. at 1378 Forest St, Denver, CO 80220:  On and before June 4, 2011, the exposing employer did not ensure that each employee installing a new sewer line inside an excavation that measured approximately 10 feet in depth was protected from cave-in. Two employees worked in the excavation located in the middle of the street without using a complete protective system. An aluminum shoring panel system was used on the east and west sides of the excavation. The south side of the excavation was unprotected. An aluminum shoring panel located inside the excavation was placed against the north side wall; however, this panel was not connected to a protective system. This condition exposed the employee to a crushing hazard by excavation wall cave-in.\\r\\n
Recent events (1)
  • · Z (S) $2975

1926.652 E02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 1, 2011
Abate by
Sep 22, 2011
Penalty
Initial $2,975 · Current $2,975
29 CFR 1926.652(e)(2)(i):  Excavation of material to a level no greater than 2 feet below the bottom of the members of the support system was allowed when there were indications while the trench was open of a possible loss of soil from behind or below the bottom of the support system:\\r\\n(a)  Bell Plumbing and Heating Co. at 1378 Forest St, Denver, CO 80220:  On and before June 4, 2011, the exposing employer did not ensure the excavation of material to be no greater than 2 feet below the bottom of the members of the support system. Soil was removed more than 5 feet below the bottom of the aluminum shoring panels on the west and east sides of the excavation. This condition exposed subcontractor employees to the potential of a protective system failure.