OSHA Inspection: BELMONT PLATING WORKS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BELMONT PLATING WORKS in 9145 KING STREET, FRANKLIN PARK, IL 60131 (NAICS 332813). OSHA activity number 330632324.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Belmont Plating Works for free Get an email when a new federal OSHA severe-injury report for Belmont Plating Works is published. One employer, no account, unsubscribe in one click.
Site address
9145 KING STREET
City
FRANKLIN PARK
State
IL
ZIP
60131
Mailing
9145 KING STREET, FRANKLIN PARK, IL 60131
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
65
Ownership type
A

17 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 12 instances 12 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $3,927 · Current $1,600 Reduced
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of electrical shock and struck by injuries.      a) Belmont Plating Works, Inc. - Throughout the plating areas - Electric Hoists were not inspected for damage and were not taken out of service until repaired.    Among other methods, one feasible and acceptable means of abatement to correct this hazard is to conform with the requirements of the American Society of Mechanical Engineers for Overhead Hoists (Underhung) - ASME B30.16-2007, Inspection, Testing, and Maintenance, chapter 16-2.1-16-2.1.3., by requiring the implementation of the frequent and periodic inspections for the hoist, ropes and slings.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $3927

1910.22 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $1,964 · Current $825 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    The employer did not ensure that all places of employment and passageways be kept in an orderly condition.    a) In Building #1 - The Electroless Plating Area - The walking platform had uneven heights; 4", 9", and 7".  The 7" platform was not flush to the platform edge due to a water pipe running below the platform.  Employees were exposed to slip, trip and falls due to the uneven platform heights.
Recent events (2)
  • · I (S) $825
  • · Z (S) $1963.5

1910.23 A08 II

Serious Gravity 1 2 instances 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $1,964 · Current $825 Reduced
29 CFR 1910.23(a)(8)(ii):     Every floor hole into which persons could accidentally walk were not guarded by a floor hole cover of standard strength and construction:    The employer falied to ensure that every floor hole into which persons could accidently walk were guarded by a floor hole cover of standard strength and construction.    a) In Building #2 - A floor hole on the grated platform measuring approximately (4"x12") were not guarded by a floor hole cover.    b) In Building #1 - A floor hole in the concrete measuring approximately (12"x20') were not guarded by a floor hole cover.
Recent events (2)
  • · I (S) $825
  • · Z (S) $1963.5

1910.23 C01

Serious Gravity 1 1 instance 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $1,964 · Current $825 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings.    a) In Building #2 - The platform in the plating area did not have a standard top and mid rail.
Recent events (2)
  • · I (S) $825
  • · Z (S) $1963.5

1910.23 D01 III

Serious Gravity 5 2 instances 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $3,927 · Current $1,600 Reduced
29 CFR 1910.23(d)(1)(iii):     Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:      The employer failed to ensure that stairways less than 44 inches wide having both sides open have a stair railing on each side.    a)  In Building #2 - The metal stairs leading to the platform with 4 or more risers did not have a railing on either side.    b)  In Building #2 - The wooden stairs leading to the platform with 4 or more risers did not have a railing on either side.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $3927

1910.24 C

Serious Gravity 5 1 instance 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $3,927 · Current $1,600 Reduced
29 CFR 1910.24(c):     Fixed stairway(s) were not designed and/or constructed to carry a load of five times the normal live load anticipated or the strength to carry safely a moving load of 1000 pounds:    a) In Building #2 - At the Zinc Plating Tanks - The fixed stairway had a damaged and unstable bottom stair.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $3927

1910.37 A02

Serious Gravity 1 1 instance 10 exposed
Issued
Oct 5, 2011
Abate by
Oct 13, 2011
Penalty
Initial $1,964 · Current $825 Reduced
29 CFR 1910.37(a)(2):     Exit routes must be arranged so that employees will not have to travel toward a high hazard area, unless the path of travel is effectively shielded from the high hazard area by suitable partitions or other physical barriers.      a) In Building #3 - In the Lab - An acetylene cylinder was stored within the exit route exposing employees to a greater hazard during a fire emergency.
Recent events (2)
  • · I (S) $825
  • · Z (S) $1963.5

1910.151 C

Serious Gravity 5 3 instances 40 exposed
Issued
Oct 5, 2011
Abate by
Oct 20, 2011
Penalty
Initial $3,927 · Current $1,600 Reduced
29 CFR 1910.151(c):     Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    The employer did not ensure that where employees are exposed to injurious corrosive materials, an eyewash be  accessible for immediate emergency use.    a) In Building #3 - The eyewash was not inspected and contained soil and wood debris, and there was no record of inspection.    b) In Building #2 - The eyewash was not inspected and was mounted next to a welding cart containing acetylene and oxygen cylinders, and there was not record of last inspection.     c) In Building #1 - The eyewash, record of last inspection was on 11/20/09.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $3927

1910.178 A06

Serious Gravity 5 2 instances 10 exposed
Issued
Oct 5, 2011
Abate by
Oct 20, 2011
Penalty
Initial $2,618 · Current $1,050 Reduced
29 CFR 1910.178(a)(6):     The employer did not ensure that all nameplates or markings were maintained in a legible condition:    a) In Building #2 - The TCM powered industrial vehicle did not have a visble load capacity placard.   b) In Building #3 - The Toyota powered industrial vehicle did not have a visible load capacity placard.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2618

1910.178 L06

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Oct 5, 2011
Abate by
Oct 13, 2011
Penalty
Initial $3,927 · Current $0 Reduced
29 CFR 1910.178(l)(6):     The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    a)  The employer did not ensure that each operator including temporary employees were trained and evaluated prior to operating a powered industrial vehicle as required by this paragraph (l).
Recent events (2)
  • · I (S) $0
  • · Z (S) $3927

1910.178 Q07

Serious Gravity 5 2 instances 10 exposed
Issued
Oct 5, 2011
Abate by
Oct 20, 2011
Penalty
Initial $2,618 · Current $1,050 Reduced
29 CFR 1910.178(q)(7):     Industrial trucks were not examined before being placed in service:    a) In Building #2 - The TCM powered industrial truck was not examined for damage, there was a missing fastening pin at the carriage and fork attachment.    b) In Building #3 - The Toyota powered industrial truck was not examined for damage, the tires were worn and seat was damaged.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2618

1910.184 E03 III

Serious Gravity 5 12 instances 12 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $3,927 · Current $1,600 Reduced
29 CFR 1910.184(e)(3)(iii):   Thorough inspection(s) of alloy steel chain slings were not performed by a competent person and/or did not include inspections for wear, defective welds, deformation, and/or increase in length:    Throughout the establishment - The employer did not ensure that alloy steel chain slings used on electric hoist equipment were submitted to a thorough inspection by a competent person for wear, defective welds, deformation and increase in length.    1) In Building #1 - A no name 1/2 ton electric hoist - The hoist chain and hook, and electrical lines, had visible signs of damage from corrosion.         2) In Building #2 - A Lodestar 1/2 ton electric hoist - The hoist chain and hook and electrical lines, had visible signs of damage.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $3927

1910.305 B01 II

Serious Gravity 5 6 instances 40 exposed
Issued
Oct 5, 2011
Abate by
Oct 27, 2011
Penalty
Initial $3,927 · Current $1,600 Reduced
29 CFR 1910.305(b)(1)(ii):   Unused openings in boxes, cabinets, or fittings were not effectively closed:    The employer did not ensure that openings in electrical boxes or fittings were closed.    a) In Bldg#3 - A metal junction box had a missing knockout and an unfastened face plate cover.  b) In Bldg#3 - A metal junction box had an unfastened face plate cover.   c) In Bldg#2 - A  metal junction box was damaged due to corrosion, and metal raceway was bent, and was in use with an ungrounded fan.  d) In Bldg#2 - A metal junction box was damaged due to corrosion and had an unfastened face plate cover.  e) In Bldg#2 - A metal junction box had an unfastened face plate cover.  f) In Bldg#1 - A metal junction box had a damaged face plate cover.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $3927

1910.334 A02 I

Other-than-serious 2 instances 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 13, 2011
Penalty
Initial $3,927 · Current $0 Reduced
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    a) In Bldg. #1 - The flexible cord on the (no name) ? ton electric hoist had damaged to the outer jacket and insulation.   b) In Bldg. #2 - The flexible cord on the Lodestar ? ton electric hoist had damaged to the outer jacket and insulation.   a) In Bldg. #2 - The plug on the North Tech fan had a missing ground pin and was plugged into a damaged junction box.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3927

1910.37 B06

Other-than-serious 2 instances 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 13, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6):     Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:    a) The employer did not ensure that the exit ligts in building #1 and #3 were illuminated.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 C01

Other-than-serious 5 instances 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 20, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):     Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a) The employer did not ensure that throughout Building #1 and #3 fire extinguishers were readily accessible without subjecting employees to injuries as fire extinguishers were maintained on the floor.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E03

Other-than-serious 5 instances 20 exposed
Issued
Oct 5, 2011
Abate by
Oct 13, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):     Portable fire extinguishers were not subjected to an annual maintenance check:    The employer failed to ensure that fire extinguishers were inspected, maintained and subjected to an annual maintenance check.    a) In Bldg#3 - (2) Fire extinguishers annual tag expired in May 2011.  b) In Bldg#2 - (2) Fire extinguishers annual tag expired in April 2011.  c) In Bldg#1 - (1) Fire extinguisher annual tag expired in April 2011.