MERIDIAN, ID ·
OSHA Inspection: ASQUETA'S GLASS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ASQUETA'S GLASS, INC. in 10 MILE & PINE ROADS, MERIDIAN, ID 83642 (NAICS 238150). OSHA activity number 330632357.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASQUETA'S GLASS, INC.
- Site address
- 10 MILE & PINE ROADS
- City
- MERIDIAN
- State
- ID
- ZIP
- 83642
- Mailing
- 1408 2ND SOUTH, NAMPA, ID 83651
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Jul 11, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) West side of stucture, north of main entrance; On or about 6/14/11 and at times prior thereto, an employee was installing an aluminum window frame from a suspended canopy without a means of fall protection. Note: Abatement certification is NOT required for this item.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1926.1053 B01
- Issued
- Jul 11, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) West side of stucture, north of main entrance; On or about 6/14/11 and at times prior thereto, an employee utilized an aluminum extension ladder for access while installing an aluminum window frame from a suspended canopy without extending the ladder at least 3 feet above the canopy deck. Note: Abatement certification is NOT required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238150)