Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: GONZALES FRAMING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GONZALES FRAMING, LLC in 2920 N. CENTERPOINT WAY, MERIDIAN, ID 83642 (NAICS 238130). OSHA activity number 330632498.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gonzales Framing, LLC for free Get an email when a new federal OSHA severe-injury report for Gonzales Framing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2920 N. CENTERPOINT WAY
City
MERIDIAN
State
ID
ZIP
83642
Mailing
2209 CALDWELL BLVD, #52, NAMPA, ID 83651
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
Private (A)

1 citation on file for this inspection.

1926.501 B13

Repeat Gravity 5 2 instances 1 exposed
Issued
Jul 25, 2011
Penalty
Initial $7,200 · Current $7,200
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    a) South side on roof; On or about 6/14/11 and at times prior thereto, an employee was installing sheathing without a means of fall protection.    b) Northwest corner at top of exterior wall; On or about 6/14/11 and at times prior thereto, an employee was trimming truss ends while walking on/working from the top of the wall without a means of fall protection.    Note: Abatement certification and documentation are NOT required for this item.    Gonzales Framing, LLC was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection 313351421, Citation 01, Item 002, and was affirmed as a final order on 2/18/10 with respect to a workplace located at Picard Drive & Centerpoint Avenue, Meridian, ID.
Recent events (1)
  • · Z (R) $7200

View Gonzales Framing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330632498.