Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TREASURE VALLEY FOREST PRODUCTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TREASURE VALLEY FOREST PRODUCTS in 7789 S. FEDERAL WAY, BOISE, ID 83716 (NAICS 321113). OSHA activity number 330632720.

Watch Treasure Valley Forest Products — free Get an email when a new federal OSHA severe-injury report for Treasure Valley Forest Products is published. One employer, no account, unsubscribe in one click.
Site address
7789 S. FEDERAL WAY
City
BOISE
State
ID
ZIP
83716
Mailing
P.O. BOX 170078, BOISE, ID 83717
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
15
Ownership type
A

12 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 3 instances 1 exposed
Issued
Jun 29, 2011
Abate by
Aug 11, 2011
Penalty
Initial $4,200 · Current $4,200
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      (a)	On 6/15/ 2011, and at times prior thereto, the employer could not provide documentation of the lock out / tag out procedures to follow when changing the blades on equipment such as but not limited to: debarker, Cut off saw, C Frame head rig saw, Schumer edger gang saw.  (b)	On 06/15/11, and at times prior thereto, lock out / tag out procedures for employees operating, adjusting, un jamming and cleaning equipment such as but not limited to the in feed and out feed conveyors of the cut off saw,  C Frame head rig, Schumer edger  gang saw were not developed.  (c)	On 6/15/2011 and at times prior thereto the employer could not provide documentation of the lock out / tag out procedures to follow when changing the knives/ hammers on the Hammer mill and sizing conveyors.    Note: Abatement certification and documentation ARE required for this item.
Recent events (1)
  • — Z (S) $4200

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $2,400 · Current $2,400
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform   were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):       (a)	On 06/15/11, and at times prior thereto, the primary drive pulley to the cut off saw was not guarded.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (S) $2400

1910.219 E02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(2)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to  the requirements specified at 29 CFR 1910.219(m) and (o    (a)	On 06/15/11 and at times prior thereto, the primary drive belts for the cut off saw were not guarded.    Note: Abatement certification IS required for this item
Recent events (1)
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprockets, wheels and chains which were seven (7) feet or less above the floor or platform were not enclosed:    (a)	On 06/15/11 and at times prior thereto, chains and sprockets, on the cut off saw scrap conveyor were not effectively guarded to prevent employees from injury.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (S) $0

1910.265 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $2,400 · Current $2,400
29 CFR 1910.265(c)(4)(ii): Walkways were not kept in good repair.    (a)	On 6/15/2011, and at times prior thereto, the cat walk along the cut off saw had four holes (4.5 inches x 12 inches) for the kicker/hold down dogs that posed a trip hazard.    Note: Abatement certification IS required for this item
Recent events (1)
  • — Z (S) $2400

1910.265 C04 IV

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.265(c)(4)(iv): Elevated walks, runways, or platforms, 4 feet or more above the floor level, were not provided with both a standard railing  and a toe board:    (a)	On 06/15/11, and at times prior thereto, employees were exposed to moving logs that feed into the debarker where the end rail was missing.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (S) $0

1910.265 E01 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.265(e)(1)(v): An effective barrier was not provided to prevent employees from entering the space necessary for travel of the carriage, with headblocks fully receded, for the full length and extreme ends of carriage runways. Warning signs were not be posted at possible entry points to this area.                                                                               (a)	On 6/15/2011, and at times prior thereto, the C frame head rig saws were not effectively guarded or signed to prevent accidental access and exposure to rotating circular saw blades.      Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (S) $0

1910.37 E

Other-than-serious 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 14, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.37(e): The employer did not assure that fire alarm signialing systems were maintained and tested in accordance with the requirements of 29 CFR 1910.165(d):    (a)   On 06/15/2011 the only means to alert employees to a fire or emergency was for supervisors to walk to each employee and verbally inform them of the emergency.    Note: Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $0

1910.38 B

Other-than-serious 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Aug 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.38(b):  An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees.    (a)   On 6/15/2011, the employer did not have a written emergency action plan to address items such as fires or medical emergency.    Note: Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $0

1910.133 A01

Other-than-serious 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment    (a)	On 06/15/11 and at times prior thereto, employees used wood cutting equipment such as the debarker, chop saw, C frame head rig, without benefit of eye or face protection when cutting.    (b)	On 06/15/2011 and at times prior thereto, employees used the DeWalt metal cutting chop saw without benefit of eye or face protection when cutting.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (O) $0

1910.243 A01 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 29, 2011
Abate by
Jun 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.243(a)(1)(i): Portable power driven circular saw(s) having a blade diameter greater than two inches were not equipped with guard(s) below the base plate or shoe which automatically and instantly returned to the covering position when the tool was withdrawn from the work:     (a)	On 06/15/11 and at times prior thereto, the lower guard on the DeWalt abrasive wheel saw did not function.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 2 instances 1 exposed
Issued
Jun 29, 2011
Abate by
Jul 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a)	On 06/15/11 and at times prior thereto, the conveyor motor power supply under the cut off saw was missing the top cover.    (b)	On 06/15/2011 and at times prior thereto, the conduit pull box and fittings on the debarker operators cab were missing covers.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330632720.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.