Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J. EAGLE FRAMING CO. LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J. EAGLE FRAMING CO. LLC in 732 DRAW STREET, BRIGHTON, CO 80601 (NAICS 238130). OSHA activity number 330632829.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J. Eagle Framing CO. LLC — free Get an email when a new federal OSHA severe-injury report for J. Eagle Framing CO. LLC is published. One employer, no account, unsubscribe in one click.
Site address
732 DRAW STREET
City
BRIGHTON
State
CO
ZIP
80601
Mailing
14470 E. 13TH AVE. D-11, AURORA, CO 80011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 4 instances 4 exposed
Issued
Jun 20, 2011
Abate by
Jun 27, 2011
Penalty
Initial $2,040 · Current $2,040
29 CFR 1926.102(a)(1):  Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:         a)  J. Eagle Framing Co. LLC at 732 Draw Street, Brighton, CO 80601:  On or before 6/4/11, the employer did not ensure that employees wore safety glasses when using pneumatic nail guns and circular saws.  Conditions exposed employees to the hazard of projectiles to the eyes.    Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (S) $2040

1926.403 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 20, 2011
Penalty
Initial $2,550 · Current $2,550
29 CFR 1926.403(b)(2):  Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:         a)  J. Eagle Framing Co. LLC at 732 Draw Street, Brighton, CO 80601:  On or before 6/4/11, the employer did not ensure that electrical equipment was installed and used in accordance with instructions, in that a metal 110 volt 4 plex receptacle outlet box was connected to a flexible cord and 220 volt plug, and plugged into the 220 volt receptacle in the temporary panel.  This metal 4 plex receptacle outlet box had holes in the back, was mssing a knockout, was set on the soil, and was not listed or labelled for such use.  This box was connected to three 110 volt extension cords used to power the air compressor and skilsaws.  Condition exposed employees to electrical shock hazards.    Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (S) $2550

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 20, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii):  Alll 120-volt, single-phase 15- and 20-ampere receptacleoutlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection:         a)  J. Eagle Framing Co. LLC at 732 Draw Street, Brighton, CO 80601:  On or before 6/4/11, the employer did not ensure that all 120 volt circuits had approved ground fault circuit interruption.  The metal 110 volt 4-plex outlet box was plugged into a 220 volt outlet and did not provide GFCI protection.  Three extension cords were plugged into the metal outlet box to power the air compressor and skilsaws, and these tools were not double insulated.  Conditions exposed employees to electrical shock hazards of up to 220 volts.     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (S) $0

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 20, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:         a)  J. Eagle Framing Co. LLC at 732 Draw Street, Brighton, CO 80601:  On or before 6/4/11, the employer did not ensure that the protable tools were properly grounded in the following instances:         1)  The metal 4-plex outlet box that was connected to 3 extension cords was not grounded.  The extension cords powered the air compressor, and other skilsaws.  The metal outlet box was connected to a 220 volt outlet and was not on ground fault circuit interrupter.  The tools were not double insulated;  and           2)  A skilsaw model H08425 Serial number HF706183 was missing its ground plug.    Conditions exposed employees to electrical shock hazards of up to 220 volts.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 4 instances 4 exposed
Issued
Jun 20, 2011
Penalty
Initial $2,550 · Current $2,550
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected frpm falling:         a)  J. Eagle Framing Co. LLC at 732 Draw Street, Brighton, CO 80601:  On or before 6/4/11, the employer did not ensure that employees were protected from falling by a guardrail system, personal fall arrest system, or a safety net in the following instances:         1)  An employee was sheathing the roof while standing on a 4' x 8' OSB with a 6 in 12 pitch, with no fall protection;         2)  Employees were framing the interior of the house, and the following second floor window openings were not guarded:         a)  One window opening on the east side measured 35" high from the floor and 6' long; and         b)  Two window openings on the west side measured 35" high from the floor and 5' long.    Conditions exposed employees to fall hazards of up to 17'.    Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (S) $2550

View J. Eagle Framing CO. LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330632829.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.