Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAITO FOOD SERVICE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CAITO FOOD SERVICE, INC. in 500 ENTERPRISE ROAD, NEWCOMERSTOWN, OH 43832 (NAICS 424480). OSHA activity number 330633058.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Caito Food Service, INC. — free Get an email when a new federal OSHA severe-injury report for Caito Food Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
500 ENTERPRISE ROAD
City
NEWCOMERSTOWN
State
OH
ZIP
43832
Mailing
500 ENTERPRISE ROAD, NEWCOMERSTOWN, OH 43832
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424480
Employees
73
Ownership type
A

3 citations on file for this inspection.

1910.333 A

Serious Gravity 5 6 exposed
Issued
Jun 29, 2011
Abate by
Aug 19, 2011
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.333(a):     "General." Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized.The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards.    a. At the workplace, for employees who routinely perform work on or near energized parts (240 VAC) such as testing, troubleshooting, voltage measuring, and other tasks in and around the electrical panel box for the dock plates, neither a flash hazard analysis was conducted to determine the proper protection required nor was a flash protection boundary established to protect employees from shock, arc flash, or arc blast.     ABATEMENT NOTE: One method of abatement, among others, includes conducting a flash hazard analysis in compliance with NFPA 70E Standard for Electrical Safety in the Workplace to determine the flash protection boundary and the use of electrical protective equipment as necessary for the specific related hazards of each task.
Recent events (2)
  • — I (S) $4250
  • — Z (S) $4250

1910.335 A01 I

Serious Gravity 5 1 exposed
Issued
Jun 29, 2011
Abate by
Aug 19, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i):     Employees working in areas where there are potential electrical hazards shall be provided with,and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to beperformed.Note: Personal protective equipment requirements are contained in subpart I of this part.    a. At the workplace, for employees who routinely perform work on or near energized parts (240 VAC) such as testing, troubleshooting, voltage measuring, and other tasks in and around the electrical panel box for the dock plates,employees did not wear and were not provided with the necessary personal protective equipment to protect employees from shock, arc flash, or arc blast.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 C02

Serious Gravity 5 1 exposed
Issued
Jun 29, 2011
Abate by
Aug 19, 2011
Penalty
Initial $4,250 · Current $0 Reduced
29 CFR 1910.333(c)(2):     "Work on energized equipment." Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.    a. At the workplace, for employees who routinely perform work on or near energized parts (240 VAC) such as testing, troubleshooting, voltage measuring, and other tasks in and around the electrical panel box for the dock plates, employees were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, and insulating and shielding materials to protect employees from shock, arc flash, or arc blast.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4250

View Caito Food Service, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330633058.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.