Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MTN HOME AFB

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MTN HOME AFB in 366 GUN FIGHTER AVE., MOUNTAIN HOME A F B, ID 83648 (NAICS 928110). OSHA activity number 330633090.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MTN Home AFB — free Get an email when a new federal OSHA severe-injury report for MTN Home AFB is published. One employer, no account, unsubscribe in one click.
Establishment
MTN HOME AFB
Site address
366 GUN FIGHTER AVE.
City
MOUNTAIN HOME A F B
State
ID
ZIP
83648
Mailing
366 GUN FIGHTER AVE., MOUNTAIN HOME A F B, ID 83648
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
722
Ownership type
D

12 citations on file for this inspection.

1960.8 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 25, 2011
Abate by
Aug 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1960.8(a): The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to a serious crush-by hazard that could result in injury or death by workiing on an Oshkosh snow sweeper without the hood access safety pin being installed.    a) VM #2 Bldg 1100:  on June 3, 2011, and times prior thereto, vehicle mechanics were working on an Oshkosh snow sweeper with out the hood safety pin installed in the engine hood lockout brace.    Note 1: Among other methods, one feasible and acceptable means of abatement would be for the employer to follow the vehicle technical manual, TO 36C18-44-1, dated September 1, 1991  "Operation and Operator Maintenance Instructions" that requires:    Chapter 3-4.6.1 Drive Engine Access-  "Warning, do not work in drive engine compartment unless hitch pin is installed in lockout strut.  If pin is not installed, lockout strut could accidently collapse causing the hood to fall.  Failure to comply could result in serious injury to personnel.     Note 2: Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.169 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.169(b)(2): Air receiver(s) were not drained frequently and at such intervals as to prevent the accumulation of excessive amounts of liquid in the receiver:    a) CE Power Production Building 1351: On June 3, 2011, and times prior thereto, employees were exposed to a pressure vessel hazard from a shop air compressor that had not been drained on a regularly scheduled basis.     Note: Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.169 B03 IV

Serious Gravity 5 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.169(b)(3)(iv): Safety valve(s) on compressed air receiver(s) were not tested at frequent, regular intervals to determine if they were in good operating condition:    a) CE Power Production building 1351: On June 3, 2011, and times prior thereto, employees were exposed to an air reciever that the safety valve had not been tested at regular intervals.    Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Recycle facility building 1800:  On June 3, 2011, and times prior thereto, employees were exposed to a machine hazard from a moving conveyor that supplies materials for crushing to the crusher/compactor that is not adequately guarded at the point of operation. In the case of an accidental fall that rendered the operator unconscious, there would be no guarding mechanism to prevent the operator from being carried into the crusher/compactor.    Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a) Packing and crating building 1320: On June 3, 2011, and times prior thereto, employees were exposed to a pedestal grinder that was not anchored to the floor.      Note: Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Environmental Controls Maintenance building 1300: On June 3, 2011, and times prior thereto, employees were exposed to unguarded pulleys from portable SMITHCO spray pump units.    Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.244 A02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(2)(v): All jacks were not properly lubricated at regular intervals.    a) Pavements and Equipment building 1327: On June 3, 2011, and times prior thereto, employees were exposed to a 10 ton hydraulic floor jack that had not been lubricated at regular intervals.    Note: Abatement certification is required for this item
Recent events (1)
  • — Z (S) $0

1910.244 A02 VI A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(2)(vi)(a): Each jack used constantly or intermittently at a single locality was not thoroughly inspected at least once every six months:    a) Pavements and equipment shop building 1327: On June 3, 2011, and times prior thereto, employees wre exposed to a 10 ton Norco hydraulic floor jack that was not inspected at least once every 6 months.    Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.333 C02

Serious Gravity 10 7 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2): Qualified persons were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools:    a) HVAC shop building 1301: On June 3, 2011, and times prior thereto, employees were exposed to electric shock from live, uninsulated 115 and 240 volt energized circuits while bench testing electric motors and other electrical components without wearing proper personal protective gloves.    Note: Abatement documentation and certification is required for this item.
Recent events (1)
  • — Z (S) $0

1910.242 A

Other-than-serious 1 instance 2 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:    a) Packing and crating building 1320: On June 3, 2011, and times prior thereto, employees were exposed to an air pressure hazard from a frayed compressed air hose being used to supply the shop air supply outlets for pneumatic tools.    Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $0

1910.303 B07 I

Other-than-serious 2 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:    a) Power Production building 1351: On June 3, 2011, and times prior thereto, employees were exposed to an energized disconnect switch that had an unused opening that was not closed.    Note: Abatement certification is required for this item
Recent events (1)
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 2 instances 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) Recycle builiding 1800:  On June 3, 2011, and times prior thereto, employees were exposed to an electric shock hazard from an electrical outlet cover that was not effectively closed.    b) Golf Course maintenance building 1804: On June 3, 2011, and times prior thereto, employees were exposed to an electric shock hazard from an electrical junction box cover that was not effectively closed.    Note:  Abatement certification is required for this item.