Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MC CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MC CONTRACTING in 100 7TH AVE, MORTON, IL 61550 (NAICS 238160). OSHA activity number 330768805.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MC Contracting — free Get an email when a new federal OSHA severe-injury report for MC Contracting is published. One employer, no account, unsubscribe in one click.
Establishment
MC CONTRACTING
Site address
100 7TH AVE
City
MORTON
State
IL
ZIP
61550
Mailing
2509 WEST ALTA ROAD, PEORIA, IL 61615
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 5 1 exposed
Issued
Jul 19, 2011
Abate by
Jul 20, 2011
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provisionin paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it isinfeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets therequirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fallprotection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complieswith 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    An Employee conductin roofing activities on a residential roof was exposed to fall hazards of approximately 7.5 feet. No fall protection was utilized.
Recent events (3)
  • — F (S) $0
  • — C (S) $3600
  • — Z (S) $3600

1926.1053 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 19, 2011
Abate by
Jul 20, 2011
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1926.1053(b)(1):     Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)    An employee accessing/egressing a roof was exposed to fall related hazards of approximately 7.5 feet.  The side rails of the ladder did not extend at least 3 feet above the upper landing surface.
Recent events (3)
  • — F (S) $0
  • — C (S) $3600
  • — Z (S) $3600

View MC Contracting's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330768805.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.