Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOFECO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOFECO INC. in 900 E. 120TH STREET, CHICAGO, IL 60628 (NAICS 238160). OSHA activity number 330769308.

Watch Sofeco INC. — free Get an email when a new federal OSHA severe-injury report for Sofeco INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SOFECO INC.
Site address
900 E. 120TH STREET
City
CHICAGO
State
IL
ZIP
60628
Mailing
4114 COVE LANE #B, GLENVIEW, IL 60025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1926.501(b)(4)(i):     Each employee on walking/working surfaces shall be protected from falling through holes(including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around suchholes:    a.  On or about June 7, 2011, at the above addressed jobsite, employees performing roofing operations on a low slope roof were exposed to falls of nineteen (19) feet through unprotected skylights.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.501 B10

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(10):     "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section,each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall beprotected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrailsystem, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safetymonitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring systemalone [i.e. without the warning line system] is permitted:    a.  On or about June 7, 2011, at the above addressed jobsite, employees performing roofing operations on a low slope roof, nineteen (19) feet above the ground, were not protected from falls, thereby exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View SOFECO INC.'s full OSHA safety record →