Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MURFIN DRILLING CO. INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MURFIN DRILLING CO. INC. in RIG 20, NESE, SEC 12, TWN 12, RNG 12, CHEYENNE WELLS, CO 80810 (NAICS 211111). OSHA activity number 330769712.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Murfin Drilling CO. INC. — free Get an email when a new federal OSHA severe-injury report for Murfin Drilling CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
RIG 20, NESE, SEC 12, TWN 12, RNG 12
City
CHEYENNE WELLS
State
CO
ZIP
80810
Mailing
250 N. WATER SUITE 300, WICHITA, KS 67202
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211111
Employees
160
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Other-than-serious 2 exposed
Issued
Sep 19, 2011
Abate by
Sep 20, 2011
Penalty
Initial $4,950 · Current $3,465 Reduced
OSH ACT of 1970 Section (5)(a)(1): \r\n\r\nSection 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falling, struck by, and burn hazards:\r\n\r\na)  On or about April 21, 2011 and at times prior, Murfin Drilling Company Inc. did not ensure that employees were protected from the hazards of an improperly erected Geronimo safety line.      1.  The escape line had no deceleration section for the safe landing of personnel    2.  The escape line was attached to a semi trailer in a manner and height which would force the employees to jump off the T-bar at a height of 8-10 feet or hit the trailer.    3.  The T-bar was attached outside of the work platform along the mast ladder.  This creates a very difficult position to try and mount the escape device.      Among other methods, one feasible and acceptable abatement method to correct the hazard is:  Develop a method of erecting the escape line which places the device at a ready for use positon at the platform, provide a tested anchor and length of wire rope which allows for proper placement of the line, and train personnel in proper erection and use of system.
Recent events (2)
  • — I (O) $3465
  • — Z (S) $4950

5(a)(1)

Deleted Serious Gravity 5 4 exposed
Issued
Sep 19, 2011
Abate by
Sep 20, 2011
Penalty
Initial $4,950 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical/lightening hazards:    a)  On or about April 21, 2011 and at times prior, Murfin Drilling Company Iinc. did not ensure that employees were  protected from electrical hazards.  The grounding rods were not properly installed or not installed at all at the toolpusher's trailer, fuel trailer, and the mud mixiing area.    Among other methods, one feasible and acceptable method toc orrect this hazard is to ensure that all equipment is properly grounded in accordance with API RP 54, Section 6.1.16.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4950

1910.132 A

Other-than-serious 1 exposed
Issued
Sep 19, 2011
Abate by
Sep 21, 2011
Penalty
Initial $4,950 · Current $4,950
29 CFR 1910.132(a):     Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a)  On or about April 21, 2011 and att times prior, Murfin Drilling Company did not ensure that employees were protected from fire hazards.  The crew was not provided with appropriate Personal Protective Equipment (PPE) such as flame-resistant clothing.
Recent events (2)
  • — I (O) $4950
  • — Z (S) $4950

1910.219 B02

Other-than-serious 4 exposed
Issued
Sep 19, 2011
Abate by
Sep 20, 2011
Penalty
Initial $4,950 · Current $2,500 Reduced
29 CFR 1910.219(b)(2):     Crank(s) or connecting rod(s) exposed to contact were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) or by guardrail(s) as described in CFR 1910.219(o)(5)    a)  On or about April 21, 2011 and at times prior, Murfin Drilling Co. Inc. did not ensure that employees were protected from mechanical power transmission apparatus hazards.  The covers over the mud pump pony rods were removed and not replaced.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $4950

1910.219 D01

Other-than-serious 4 exposed
Issued
Sep 19, 2011
Abate by
Sep 20, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)  On or about April 21, 2011 and at times prior, Murfin Drilling Co. Inc. did not ensure that employees were protected from mechanical power transmission hazards.  The shale shaker on the mud tanks had exposed pulleys due to damage of the cover.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.219 E01 I

Other-than-serious 4 exposed
Issued
Sep 19, 2011
Abate by
Sep 20, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i):     Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):    a)  On or about April 21, 2011 and at times prior, Murfiin Drilling Co. Inc did not ensure that employees were protected from mechanical power transmission hazards.  The shaker on the mud pits had exposed belts due to damage done to the cover.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 1 exposed
Issued
Sep 19, 2011
Abate by
Sep 20, 2011
Penalty
Initial $3,960 · Current $3,960
29 CFR 1910.305(g)(2)(ii):     Flexible cords were not used in continuous lengths without splice or tap:    a)  On or about April 21, 2011 and at times prior, Murfin Drilling Co. Inc. did not ensure that employees were protected from electrical hazards.  The microwave in the doghouse had a light gauge extension cord spliced to the prongs of the microwave cord.  The splice consisted of exposed conductors twisted around the plug prongs and then wrapped with electricians tape.  This does not bring the connections to the manufacturers specifications.
Recent events (2)
  • — I (S) $3960
  • — Z (S) $3960

View Murfin Drilling CO. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330769712.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.