Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: MADRIGAL, OSWALDO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MADRIGAL, OSWALDO in 2250 SPRUCE STREET, BOULDER, CO 80302 (NAICS 238170). OSHA activity number 330770009.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Madrigal, Oswaldo for free Get an email when a new federal OSHA severe-injury report for Madrigal, Oswaldo is published. One employer, no account, unsubscribe in one click.
Establishment
MADRIGAL, OSWALDO
Site address
2250 SPRUCE STREET
City
BOULDER
State
CO
ZIP
80302
Mailing
9850 FEDERAL BLVD. LOT 99, FEDERAL HEIGHTS, CO 80260
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
Private (A)

5 citations on file for this inspection.

1926.1053 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 23, 2011
Penalty
Initial $1,530 · Current $1,071 Reduced
29 CFR 1926.1053(b)(1):  When portable ladders were used for access to an upper landing surface, the ladder side rails were not extended at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access or were not secured:           a)  Madrigal, Oswaldo dba Valdo's Construction at 2250 Spruce Street, Boulder, CO 80302:  On or before 6/18/11, the employer did not ensure that a ladder used to gain access to the second floor porch had its side rails extended up 3 rungs or was secured.  Condition exposed employees to fall hazards of 12'9".     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1530

1926.1053 B16

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not  immediately marked in a manner that readily identifies them as defective, or were tagged with "Do Not Use" or similar language and withdrawn from service until repaired:          a)  Madrigal, Oswaldo dba Valdo's Construction at 2250 Spruce Street, Boulder, CO 80302:  On or before 6/18/11, the employer did not ensure that a ladder used to gain access to the second floor porch, and which included damaged rungs on the 1st, 2nd, and 4th steps, was tagged and removed from service.  Condition exposed employees to fall hazards of 12'9".     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.404 B01 II

Other-than-serious 2 instances 3 exposed
Issued
Jun 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii):  All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which were not a part of the permanent wiring of the building or structure and which were in use by employees, did not have approved ground-fault circuit interrupters for personnel protection:      a)  Madrigal, Oswaldo dba Valdo's Construction at 2250 Spruce Street, Boulder, CO 80302:  On or before 6/18/11, the employer did not ensure that a working GFCI was on site.  The electrical circuits were used to power a 110 volt skilsaw that was not double insulated, and a 6 gallon Porter Cable air compressor.  Conditions exposed employees to electrical shock hazards.     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.404 F06

Other-than-serious 2 instances 3 exposed
Issued
Jun 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, and enclosures was not permanent and continuous:         a)  Madrigal, Oswaldo dba Valdo's Construction at 2250 Spruce Street, Boulder, CO 80302:  On or before 6/18/11, the employer did not ensure that the following electrical circuits were grounded:         1)  One orange extension cord and one yellow three-way splitter cord were missing their ground plugs, and were used to power a 110 volt Skilsaw and a 110 volt 6 gallon Porter Cable air compressor;         2)  The plug to the skilsaw was missing its ground plug.  The skilsaw was not double insulated;         3)  The plug to the 6 gallon Porter Cable air compressor was missing its ground plug.       Conditions exposed employees to electrical shock hazards.     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.405 A02 II I

Other-than-serious 2 instances 3 exposed
Issued
Jun 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I):  Flexible cords and cables were not protected from damage. Sharp corners and projections were not avoided. Flexible cords and cables passed through doorways or other pinch points, and protection was not provided to avoid damage:         a)  Madrigal, Oswaldo dba Valdo's Construction at 2250 Spruce Street, Boulder, CO 80302:  On or before 6/18/11, the employer did not ensure that extension cords were protected from damage.  An orange cord was laid across an access road, and was not protected.  Two other cords were tied in knots to secure connections, and had damaged insulation.  The cords were used to power a 110 volt skilsaw and a 110 volt 6 gallon Porter Cable air compressor.  Conditions exposed employees to electrical shock hazards.     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330770009.