Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AURORA CIRCUITS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AURORA CIRCUITS in 2250 WHITE OAK CIRCLE, AURORA, IL 60504 (NAICS 334418). OSHA activity number 330770686.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aurora Circuits — free Get an email when a new federal OSHA severe-injury report for Aurora Circuits is published. One employer, no account, unsubscribe in one click.
Establishment
AURORA CIRCUITS
Site address
2250 WHITE OAK CIRCLE
City
AURORA
State
IL
ZIP
60504
Mailing
2250 WHITE OAK CIRCLE, AURORA, IL 60504
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334418
Employees
53
Ownership type
A

5 citations on file for this inspection.

1910.132 A

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 6, 2011
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:      Employees were not provided aprons while adding sodium persulfate to change the bath water on the OSP/Cleanline in the fabrication department.      There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.303 B07 IV

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 6, 2011
Abate by
Oct 19, 2011
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.    The internal components of the heating unit for the Roll Tin Machine were deteriorated by corrosion which could affect the safe operation and mechanical strength of the equipment.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.303 E

Other-than-serious 1 instance 6 exposed
Issued
Sep 6, 2011
Abate by
Oct 19, 2011
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.303(e): \r\n\r\nMarkings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary: Maintenance employees were exposed to electrical shock hazards while servicing the back of the Roll Tin Machine located in the fabrication department without the equipment having the proper voltage marking. \r\n\r\nAbatement certification is required of this item in accordance of the requirements of the 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

1910.335 A01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 6, 2011
Abate by
Oct 19, 2011
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.335(a)(1)(i):     Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    Maintenance employees were exposed to electrical shock hazards while servicing the Roll Tin Machine located in the fabrication department while energized without the proper personal protective equipment.     Abatement documentation is required of this item in accordance of the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.335 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 6, 2011
Abate by
Oct 19, 2011
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.335(a)(2)(i): \r\n\r\nWhen working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:\r\n\r\nMaintenance employees were exposed to electrical shock hazards while servicing the Roll Tin Machine located in the fabrication department while energized without using proper insulated tools. \r\n\r\nAbatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330770686.