URBANA, IL ·
OSHA Inspection: D&S SEWER SERVICE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D&S SEWER SERVICE, INC. in 803 EAST OREGON, URBANA, IL 61802 (NAICS 237110). OSHA activity number 330772674.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D&S SEWER SERVICE, INC.
- Site address
- 803 EAST OREGON
- City
- URBANA
- State
- IL
- ZIP
- 61802
- Mailing
- 1907 COUNTY SQUIRE ROAD, URBANA, IL 61802
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.652 A01
- Issued
- Jul 19, 2011
- Abate by
- Aug 16, 2011
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) sloping and benching systems, or paragraph (c) support systems, shield systems, and other protective systems: Employees were working in an excavation at a depth up to 5.6 feet preparing the sub grade, cutting tree roots, and pushing the existing pvc sewer line under the sidewalk, and the excavation was not sloped, shored, or braced in accordance with the standard. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- · I (S) $3600
- · Z (S) $3600
1926.20 B01
- Issued
- Jul 19, 2011
- Abate by
- Aug 16, 2011
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: Employees were working in an excavation preparing the sub grade, cutting tree roots, and pushing the existing pvc sewer line under the sidewalk, and the employer did not initiate and maintain an accident prevention program to control and eliminate the hazards present at the jobsite in accordance with OSHA regulations. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- · I (S) $0
- · Z (S) $2400
1926.651 K01
- Issued
- Jul 19, 2011
- Abate by
- Aug 16, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: Employees were working in an excavation preparing the sub grade, cutting tree roots, and pushing the existing pvc sewer line under the sidewalk. The excavation was not inspected by a competent person before the employees were allowed to enter the working area and the excavation. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.651 C02
- Issued
- Jul 19, 2011
- Abate by
- Jul 26, 2011
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: Employees were working in an excavation at a depth up to 5.6 feet preparing the sub grade, cutting tree roots, and pushing the existing pvc sewer line under the sidewalk, and a safe means of egress was not located in the excavation. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- · I (S) $0
- · Z (S) $3600
More inspections in this industry (NAICS 237110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330772674.