ADDISON, IL —
OSHA Inspection: CJPA SCRAP METAL INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CJPA SCRAP METAL INC. in 135 W. FAY AVENUE, ADDISON, IL 60101 (NAICS 423930). OSHA activity number 330774365.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CJPA SCRAP METAL INC.
- Site address
- 135 W. FAY AVENUE
- City
- ADDISON
- State
- IL
- ZIP
- 60101
- Mailing
- 135 W. FAY AVENUE, ADDISON, IL 60101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 9
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.22 B01
- Issued
- Jan 4, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Where mechanical handling equipment was used, sufficient safe clearances were not allowed for aisles, at loading docks, through doorways and wherever turns or passage were made. Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Indoor scrap sorting floor. Various scrap materials were piled on the floor in areas where the forklift truck and skid steer loader were used. There were no clear and designated aisles and passageways for powered equipment and pedestrians. The forklift truck came to close to the customer service desk. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.110 F06 II
- Issued
- Jan 4, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.110(f)(6)(ii): Containers of liquified petroleum gas were not in a suitable enclosure or otherwise protected against tampering. Outside Storage Area. Propane tanks were stored outside of a protective storage cage. Scrap materials such as old pallets were piled on top of the tanks, subjecting them to damage. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.132 D01
- Issued
- Jan 4, 2012
- Abate by
- Feb 3, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment (PPE). Entire Facility. The employer did not conduct and certify a personal protective equipment (PPE) hazard assessment to determine the types of PPE employees should be required to wear when performing various tasks, such as steel-toed safety shoes to protect against metal scrap injuries, gloves to protect against battery acid and metal punctures and hard hats to protect against overhead or side impact hazards during the scrap sorting process. Abatement documentation is required for the item in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.136 A
- Issued
- Jan 4, 2012
- Abate by
- Feb 3, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.136(a): General requirements. The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards. Entire Facility. The employer did not require employees who worked in the inside scrap sorting area and who walked on top of scrap in outside trailers to wear steel-toed safety shoes to protect their feet against falling objects, and punctures from metal scrap. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.178 L04 III
- Issued
- Jan 4, 2012
- Abate by
- Feb 3, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. The employer did not conduct and certify a performance evaluation (driving test) for all employees authorized to operate powered industrial trucks in the workplace. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.212 A03 II
- Issued
- Jan 4, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of a machine whose operation exposed an employee to injury was not guarded. The guarding device was not in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, was not so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. Inside sort/scrap area. The guard on the Masterforce 14" cutoff was incomplete and did not protect the operator from contacting the blade during the cutting operation. No abatement documentation or certification is required for this item.
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1910.304 F01 VIII
- Issued
- Jan 4, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD." Sort and Scrap Room. Employees turned the overhead lights on and off daily by using the circuit breakers as switches. The circuit breakers were not marked "SWD", which created an arcing hazard. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.178 A06
- Issued
- Jan 4, 2012
- Abate by
- Feb 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): Powered Industrial Trucks. The user did not see that all nameplates and markings were in place and were maintained in a legible condition. The capacity label on the Toyota lift truck (42-5FG25 78275) was not legible. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jan 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling. Sort and Scrap Room, Desk Area. Relocatable power taps (electrical outlet strips) were used improperly in an industrial setting in the following instances: a. A relocatable power tap was tied onto a pipe in a vertical position and used to power a radio and time clock. b. A relocatable power tap was plugged into an extension cord and stretched in the air while used to power an industrial fan. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 I C
- Issued
- Jan 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(C): Electric Equipment Operating at 600 volts, nominal, or less to ground. The work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of this section. Sort and scrap room. A work table was placed in front and below the electrical cabinet that contained the overhead lighting circuit breakers, which restricted routine and emergency access to the breakers. Employees had to climb on the table in order to reach the breaker box. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Jan 4, 2012
- Abate by
- Feb 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at the workplace, a written hazard communication program which at least described how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training would be met, and which also included the information in paragraphs (e)(1)(i) and (e)(1)(ii). The employer did not develop, maintain and implement a written hazard communication program for employees exposed to chemicals such as, but not limited to, liquified petroleum gas and battery acid. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G08
- Issued
- Jan 4, 2012
- Abate by
- Feb 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required material safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s). (Electronic access, microfiche, and other alternatives to maintaining paper copies of the material safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.) The employer did not have material safety data sheets for the hazardous chemicals employees were exposed to such as, but not limited to, liquified petroleum gas and battery acid. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423930)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330774365.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.