Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: AMMON ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMMON ENTERPRISES, INC. in 2215 W. 111TH ST., CHICAGO, IL 60643 (NAICS 238140). OSHA activity number 330920794.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ammon Enterprises, INC. for free Get an email when a new federal OSHA severe-injury report for Ammon Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2215 W. 111TH ST.
City
CHICAGO
State
IL
ZIP
60643
Mailing
5639 W. 151ST ST., OAK FOREST, IL 60452
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.416 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 19, 2011
Abate by
Aug 22, 2011
Penalty
Initial $1,800 · Current $1,000 Reduced
29 CFR 1926.416(e)(1):   Worn or frayed electric cords or cables shall not be used:    a. On or about July 8, 2011, at the above addressed jobsite, an extension cord used to power mixing equipment was damaged, thereby exposing employees to the hazards associated with electric shock.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1800

1926.451 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 19, 2011
Abate by
Aug 22, 2011
Penalty
Initial $4,200 · Current $2,000 Reduced
29 CFR 1926.451(b)(2):  except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide:    a.  On or about July 8, 2011, at the above addressed jobsite employees were performing tuckpointing operations from a tubular welded frame scaffold.  The scaffold platform was not eighteen (18) inches in width, thereby exposing employees to falls of twenety four (24) feet.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $4200

1926.451 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 19, 2011
Abate by
Aug 22, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio ofmore than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means:    a.  On or about July 8, 2011, at the above addressed jobsite, employees were performing tuckpointing operations from a tubular welded frame scaffold with a height to base ratio greater than four to one (>4:1) that was not restrained from tipping, thereby exposing employees to falls.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 19, 2011
Abate by
Aug 22, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms:    a.  On or about July 8, 2011, at the above addressed jobsite, employees were performing tuckpointing operations from a tubular welded frame scaffold, twenty four (24) feet above the ground.  The scaffold did not have guardrails along all open sides, thereby exposing the employees to the hazards associated with falls.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 19, 2011
Abate by
Aug 22, 2011
Penalty
Initial $1,800 · Current $1,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portableladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used:    a.  On or about July 8, 2011, at the above addressed jobsite, employees performing tuckpointing operations from a tubular welded frame scaffold, twenty four (24) feet above the ground, were not provided a safe means of access, thereby exposing the employees to falls.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330920794.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.