Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNSTAR ENGINEERING AMERICAS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of SUNSTAR ENGINEERING AMERICAS, INC. in 700 WATKINS GLEN DR., FRANKLIN, OH 45005 (NAICS 336991). OSHA activity number 330921008.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunstar Engineering Americas, INC. — free Get an email when a new federal OSHA severe-injury report for Sunstar Engineering Americas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
700 WATKINS GLEN DR.
City
FRANKLIN
State
OH
ZIP
45005
Mailing
85 SOUTH PIONEER BLVD., SPRINGBORO, OH 45066
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336991
Employees
35
Ownership type
A

5 citations on file for this inspection.

1910.176 B

Other-than-serious 1 exposed
Issued
Jul 22, 2011
Abate by
Jul 25, 2011
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1910.176(b):  Material storage system(s) were not secured to prevent tipping or collapse:       a) In the Shipping and receiving, H-D Disc, AM-Warehouse, and VIP-Aft H/T Department areas the pallet rack and material racks systems that were loaded and unloaded by fork trucks were not secured to the floor or braced by equivalent means to protect against accidental tipping and or total collapse.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3825

1910.212 A01

Serious Gravity 10 4 instances 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $6,300 · Current $4,000 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points, rotating parts, and caught in moving parts:      Instance a); The small Grizzly Lathe located in the Die Set Maintenance Area did not have a chuck guard to protect against contact with the rotating chucks and employees utilized the lathe to debar and polish small die set pins.     Instance b): The perimeter guarding installed and located on the left hand side of the AIDA Press located in the Press Area did not have a working interlock switch to shut down rotating and conveying feed equipment to the AIDA Press when the gate was opened and the operator and helper periodically had to enter that gate to access and correct miss fed and or jammed parts.    Instance c): Located on the right hand side of the AIDA Press located in the Press Area did not have perimeter guarding or equivalent shielding from inadvertent contact with the part handling and reciprocating equipment where the operator enter along side the machine to make adjustment to the pick-up conveyor device.    Instance d): The parts handling equipment partially enclosed on both the K - Leveler and M- Leveler automotive controlled machines located in the Press Area did not have a guard installed to protect inadvertent contact to the pinch point created as the material handling ram equipment moved out side the machine and stop against an end bracket during machine automotive cycle.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6300

1910.219 F03

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 22, 2011
Abate by
Aug 12, 2011
Penalty
Initial $3,825 · Current $1,900 Reduced
29 CFR 1910.219(f)(3):  Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more thanseven (7) feet above the floor or platform.     Instance a)  The sprocket wheel and chain powered conveyor located approximately 20 inches above the floor at the end of the Leveler parts conveyor line where the employees off loaded parts as received was not enclosed to protect against inadvertent contact and the ingoing nip points created by that equipment.     Instance b) Employees who loaded parts on the turn table power by sprocket wheel and chain located at the Heat Treat machine were exposed inadvertent contact to the ingoing nip points created by that equipment.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3825

1910.253 B02 II

Other-than-serious 5 instances 1 exposed
Issued
Jul 22, 2011
Abate by
Jul 25, 2011
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.    Instance a)  The acetylene and oxygen gas cylinders were stored together on a wheel cart and signally against the wall located in the maintenance parts room and were not secured to prevent being knocked over.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3825

1910.253 B02 IV

Other-than-serious 4 instances 1 exposed
Issued
Jul 22, 2011
Abate by
Jul 25, 2011
Penalty
Initial $500 · Current $0 Reduced
29 CFR 1910.253(b)(2)(iv):     Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.    Instance a)  Located in the maintenance parts room both the Acetylene and Oxygen gas cylinders that were not in use, which were design for valve protective caps, did not have protective caps installed on them to protect the valves from damage.
Recent events (2)
  • — I (O) $0
  • — Z (S) $500

View Sunstar Engineering Americas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330921008.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.